Instructions

: Process nput type selecton parameter. (Default: )
J type (Fe,Cu,N) Thermocouple; -200ºC,900ºC ; -328ºF,1652ºF
J type (Fe,Cu,N) Thermocouple; -199.9ºC,900.0ºC ; -199.9ºF,999.9ºF
K type (N,Cr,N) Thermocouple; -200ºC,1300ºC ; -328ºF,2372ºF
K type (N,Cr,N) Thermocouple; -199.9ºC,999.9ºC ; -199.9ºF,999.9ºF
R type (Pt13%RhPt) Thermocouple; 0ºC,1700ºC ; 32ºF,3092ºF
R tp (Pt13%RhPt) Thermocouple; 0.0ºC,999.9ºC ; 32.0ºF,999.9ºF
S tp (Pt10%RhPt) Thermocouple; 0ºC,1700ºC ; 32ºF,3092ºF
S tp (Pt10%RhPt) Thermocouple; 0.0ºC,999.9ºC ; 32.0ºF,999.9ºF
PT100 Thermoresstance; -200ºC,650ºC ; -328ºF,1202ºF
PT100 Thermoresstance; -199.9ºC,650.0ºC ; -199.9ºF,999.9ºF
: Unt selecton parameter. or can be chosen. (Default: )
: Operaton scale mnmum(Low Lmt) value. It changes accordng to
the process nput type and scale. (Default: -200)
: Operaton scale maxmum(Hgh Lmt) value. It changes accordng to
the process nput type and scale. (Default: 900)
: Process set value low lmt parameter. It can be adjusted between
Operaton Scale Mnmum( ) and Process Set Value Hgh Lmt( ).
(Default:-200)
: Process set value hgh lmt parameter. It can be adjusted between
Process Set Value Low Lmt( ) and Operaton Scale Maxmum( )
and (Default: 900)
: Process offset value. It can be adjusted as a degree( or ), from
-10% of scale to 10% of scale.It s added to the process value. (Default: 0)
: Output control type parameter. It can be selected or .
(Default: )
: Hysteress value. It can be adjusted from 1º(pont representaton:
0.1º) to 20º. (Default: 3)
: Mnmum ON/OFF control output tme parameter. It can be adjusted
from 0 to 60 seconds. (SSR Default: 0 ; Relay Default: 5)
: Proportonal band (P). It can be adjusted from %1.0 to %100.0.
(Default: 10.0)
: Output Control Perod. If control output s SSR, It can be adjusted
from 0.5 to 150.0 seconds. If control output s Relay, It can be adjusted 60.0
to 150.0 seconds. (SSR Default: 10.0 ; Relay Default: 60.0)
: Proportonal Offset value. Ths parameter s used for shftng the
proportonal band. It can be adjusted from (-Operaton Scale Maxmum /2)
to (Operaton Scale Maxmum /2). (Default: 0)
: Integral Tme. It can be adjusted from 0 to 3600 seconds.
(Default: 100)
: Dervatve Tme. It can be adjusted from 0.0 to 999.9 seconds.
(Default: 25.0)
Bakım
Adjustment of Hysteress Value for ON/OFF Control
Time
Time
Temperature
Set Value
Temperature
Control Output
Temperature
Hysteresis
In ON/OFF control algorthm, temperature value s tred to keep equal to set
value by openng or closng completely last control element. ON/OFF controlled
system, temperature value oscllates contnuously. Temperature value’s
oscllaton perod or ampltude around set value changes accordng to controlled
system. For reducng oscllaton perod of temperature value, a threshold zone
s formed below or around set value and ths zone s named hysteress. Acton
of control output s descrbed wth fgures below.
Temperature
Control Output
Temperature
Set Value
Temperature
ON/OFF
Conrol Form
with
Hysteresis
Other Informatons
Manufacturer Informaton:
a
Emko Elektronk Sanay ve Tcaret A.Ş.
Demrtaş Organze Sanay Bölges Karanfl Sk. No:6 16369
BURSA/TURKEY
a
Phone : +90 224 261 1900
Fax : +90 224 261 1912
a
Repar and Mantenance Servce Informaton:
a
Emko Elektronk Sanay ve Tcaret A.Ş.
Demrtaş Organze Sanay Bölges Karanfl Sk. No:6 16369
BURSA/TURKEY
a
Phone : +90 224 261 1900
Fax : +90 224 261 1912
Orderng Informatons
Supply Voltage
A
Customer
3
4
5
9
24VV (±%15) 50/60Hz
115VV (±%15) 50/60Hz
230VV (±%15) 50/60Hz
Input Type
BC
Confgurable20
Scale
See Parameters ( )
In package,
-One piece unit
-Two pieces mounting clamp
-One piece instruciton manual
A visual inspection of this product for possible damage occured
during shipment is recommended before installation. It is your
responsibility to ensure that qualied mechanical and electrical
technicians install this product.
If there is danger of serious accident resulting from a failure or
defect in this unit, power o the system and the electrical
connection of the device from the system.
The unit is normally supplied without a power switch or a fuse.
Use power switch and fuse as required.
Be sure to use the rated power supply voltage to protect the unit
against damage and to prevent failure.
Keep the power o until all of the wiring is completed so that
electric shock and trouble with the unit can be prevented.
Never attempt to disassemble, modify or repair this unit.
Tampering with the unit may results in malfunction, electric shock
or re.
Do not use the unit in combustible or explosive gaseous
atmospheres. During the equipment is put in hole on the metal
panel while mechanical installation some metal burrs can cause
injury on hands, you must be careful.
Montage of the product on a system must be done with it's
mounting clamp. Do not do the montage of the device with
inappropriate mounting clamp. Be sure that device will not fall
while doing the montage.
It is your responsibility if this equipment is used in a manner not
specied in this instruction manual.
Before begnnng nstallaton of ths product, please read
the nstructon manual and warnngs below carefully.
Installaton
Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects
in material and workmanship. This warranty is provided for a period of two
years. The warranty period starts from the delivery date.
This warranty is in force if duty and responsibilities which are
determined in warranty document and instruct on manual performs by the
customer completely.
Mantenance
Repairs should only be performed by trained and specialized personnel. Cut
power to the device before accessing internal parts. Do not clean the case
with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a
cloth dampened in ethyl alcohol or water to clean the external plastic
case.
Before commssonng the devce, parameters must be set n
accordance wth desred use. Incomplete or ncorrect confguraton
can cause dangerous stuatons.
Because of lmted mechancal lfe of relay output contact, SSR output
s recommended whch the devce use PID control algortm. The
devce wth ON/OFF control algortm, hysteress parameter must be
set a sutable value for your system, to avod too much relay swtchng.
V Vac,
Z Vdc,
W Vdc or Vac can be appled.
Output-1 (Temperature Control Output)
E
Relay Output (7A@250VV at Resstve Load) (NO,NC,C)
1
SSR Drver Output (Max. 10mA, 17VZ)
2
Output-2 (Tme Output)
FG
Relay Output (5A@250VV at Resstve Load) (NO,C)
01
SSR Drver Output (Max. 10mA, 17VZ)
02
Output-3 (Steam Output) (ESM-9945-N)
HI
Relay Output (5A@250VV at Resstve Load) (NO,C)
01
SSR Drver Output (Max. 10mA, 17VZ)
02
ESM-9945-N(96x96 DIN 1/4)
20
0
1
ESM-9944-N(96x96 DIN 1/4)
20
0
00
1
Access, Change and Record the Parameter Values
: If tune parameter s set to or , devce starts to calculate
PID parameters automatcally. (Default: )
: Devce does not calculate PID parameters.
: Step Response Tunng operaton.
: Lmt Cycle Tunng operaton.
:Temperature - Tme dsplay form. If parameter value set as ,only
Temperature or Tme value s dsplayed accordng to selected page. If
parameter value set as dfferent from , Temperature and Tme value s
dsplayed alternately durng parameter value. It can be adjusted from
0 to 99 seconds. (Default: )
: Tmer dsplayed form. If parameter value set as , tmer form s
Mnute-Second. If parameter value set as , tmer form s Hour-Mnute.
(Default: )
: Tmer counts drecton parameter. If the parameter set as , tmer
counts downt-to-up. If the parameter set as , tmer counts up-to-down.
(Default: )
: Tmer countng method parameter. If the parameter set as , tmer
counts actve tme. If the parameter set as , tmer counts set tme.
If parameter set as , ths parameter s not seen. (Default: )
: Tmer Relay Poston Parameter. If the parameter s , Tmer relay
becomes actve poston wth the tme start and becomes passve at the
end of the tme. If the parameter s , then tme relay becomes actve at
the end of the tme. (Default: )
: Relay actve tme parameter. If parameter value set as then
Tme End Output wll be actve contnously. If value set as a dfferent
value(from 1 to 9999 seconds), Tme End Output wll be actve durng the
entered tme. (Default: )
: Buzzer actve tme parameter. If parameter value set as ,
Buzzer wll be actve contnously. If parameter value set as a dfferent
value (from 1 to 9999 seconds), Buzzer wll be actve durng the entered
tme. (Default: )
: Dgtal nput crcut parameter. If the parameter set as , crcut s
Normally Open (NO). If the parameter set as , crcut s Normally Closed
(NC). (Default: )
: Type of command when dgtal nput actvated. If the parameter set
as , tmer stops countng and resets tme. If the parameter set as ,
tmer pauses countng. (Default: )
: Steam duraton parameter (ESM9945N). If the Steam Duraton
Parameter s selected as then the steam output wl be on durng the
Steam button s pressed. If the parameter value set as a dfferent value
(from 1 to 9999 seconds), after pressng the steam button, output wll be
on durng the Steam Duraton Parameter value. If Steam button s
pressed when steam output s on, steam output wll be off. (Default: )
: Password for accessng to the parameters secton. It can be
adjusted from 0 to 9999. If parameter value s , password screen s not
seen. If parameter value s dfferent from and ;
-If user enters dfferent value from saved value, devce wll return to
man screen automatcally.
-If user enters , all parameters can be observed except .
But devce does not allow to do any changes n parameters. (Default: )
Error Messages
Sensor falure n analog nput. If there s no
sensor connecton or the value that s read from
the analog nput goes out of the devce scale,
warnng s observed.
ESM-9945-N
SET
°C
°F
P
O1
O2
+ -
ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
Tune falure. If s selected n PID Tune
Parameter( ) and start condtons are not
okay for Tune operaton, the temperature value
s dsplayed alternately wth message on
dsplay durng 10 seconds.
Parameters Descrptons
Startng the Tune operaton
1- Enter the parameter and select or . Observe that blnks.
(If s selected and start condtons are not okay for Tune operaton,
blnks durng 10 seconds.)
2- Devce calculates PID control coeffcents and sets the process value to
wanted value.
Cancellng tune operaton:
1- If sensor breaks;
2-If tune operaton can not be completed n 8 hours;
3-Whle tune operaton s runnng, f process value becomes greater than
process set value;
4-Whle tune operaton s runnng, f user changes the process set value;
5-Whle tune operaton s runnng, f user changes the parameter n menu;
Then tune operaton s canceled and devce contnues to run wth former PID
parameters wthout changng PID parameters.
Tune Operaton
+
SET
°C
°F
P
O1
O2
++
Parameter Values Screen
To increase parameter
value, turn encoder button
right. Press encoder button
to save.
+
SET
°C
°F
P
O1
O2
++
Parameter Values Screen
To decrease parameter
value, turn encoder button
left. Press encoder button
to save.
+
SET
°C
°F
P
O1
O2
++
Parameters Screen
+
SET
°C
°F
P
O1
O2
++
Parameters Screen
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Note1: PID control parameters ( , , , , , ) are not seen when
output control type parameter ( ) s set as .
Note2: ON/OFF control parameters ( , ) are not seen when output control type
parameter ( ) s set as .
Note3: parameter s not seen when parameter set as . parameter can be
seen after parameter.
Note4: parameter s not seen n ESM9944N devce. parameter can be seen after
parameter.
Note5: If s dfferent from and user enters on password screen, parameter values
except are observed but can not be changed.
Note6: If no operaton for 20 seconds on Parameters Screen, devce automatcally returns
Man Screen .