Instructions
ESM-9944-N / ESM-9945-N
COOKING CONTROLLERS
Electr�cal W�r�ngs
D�mens�ons
ESM-9945-N
SET
°C
°F
P
O1
O2
+ -
Temperature Un�t Ind�cator
Programm�ng Mode Ind�cator
Temperature Control Output Status
T�me End Output Status
Encoder Button
Temperature Ind�cator
Steam Output Status(ESM9945N)
T�me �nd�cator
Steam Start-Stop Button
(ESM9945N)
T�me Start-Stop Button
If cooking time is not active, starts
cooking time. If cooking time is
started, cooking time is cancelled
and buzzer is silenced.
Temperature Un�t Ind�cator
Front Panel Def�n�t�on
ESM-9945-N
SET
°C
°F
P
O1
O2
+ -
96 mm / 3.78 �nch
96 mm / 3.78 �nch
84 mm / 3.31 �nch
11.5 1mm / 0.45 �nch
Max�mum 15 mm / 0.59 �nch
Panel Cut-out
92 mm / 3.62 �nch(m�n)
92 mm / 3.62 �nch(m�n)
129 mm / 5.08 �nch(m�n)
129 mm / 5.08 �nch(m�n)
Panel Mount�ng
Access and Change Set Value
Temperature Set Value
Time Set Value
Note : If no operat�on for 10 seconds, dev�ce automat�cally ex�ts from Set Value Screen w�thout sav�ng the value.
Press encoder button
to observe the set value.
Turn left encoder button
to decrease or turn r�ght
to �ncrease the set value.
Press encoder button
to save new set value
and return ma�n screen.
+
°C
°F
P
O1
O2
++
Set Value Screen
SET
ESD-9950-N
+
°C
°F
P
O1
O2
++
Ma�n ScreenMa�n Screen
+
°C
°F
P
O1
O2
++
Set Value Screen
+
°C
°F
P
O1
O2
++
Press encoder button
to observe the set value.
SET
+
°C
°F
P
O1
O2
++
Set Value Screen
Press encoder button
to save new set value
and return main screen.
Turn left encoder button
to decrease or turn right
to increase the set value.
SET
Ma�n Screen
+
°C
°F
P
O1
O2
++
SET
Set Value Screen
+
°C
°F
P
O1
O2
++
Ma�n Screen
+
SET
°C
°F
P
O1
O2
++
ESM-9944-N / ESM-9945-N Cook�ng Controllers
- 4 d�g�ts d�splay
- J type Thermocouple Input or
K type Thermocouple Input or
R type Thermocouple Input or
S type Thermocouple Input or
2 or 3 w�re PT 100 Input
- Adjustable Process Offset Value
- Programmable ON/OFF, P, PI, PD ve PID control types
- Adaptat�on of PID coeff�c�ents to the system by Auto Tune/Self Tune
- Work�ng t�me select�on �n m�nutes or seconds
- Vo�ced warn�ng v�a �nternal buzzer
- Cover sw�tch �nput
- Steam output (ESM-9945-N)
ESM-9944-N / ESM-9945-N cook�ng controllers are ma�nly used for Bakery
appl�cat�ons, fermantat�on cab�nets, ceram�cs and glass ovens, gra�n dr�er
cab�net, �ndustr�al fryer, �ncubators. Accurate and advanced controll�ng �s
performed w�th selectable ON-OFF, P, PI, PD ve PID, Self-Tune PID, Auto-
Tune PID funct�ons.
DISPLAY
Temperature D�splay: 16 mm Red 4 d�g�ts LED D�splay
Led Ind�cators: O1 (Temperature Control Output Status LED), O2 (T�me Control
Output Status LED), Steam Output LED(ESM-9945-N), T�me Ind�cator,
Temperature Ind�cator, P(Programm�ng Mode LED),ºC, ºF LEDs
OUTPUT
Temperature Control Output : Relay (7A@250VV at res�st�ve load) or opt�onal
SSR Dr�ver Output (Max�mum 10mA, 17VZ )
T�me Output : Relay (5A@250VV at res�st�ve load) or opt�onal SSR Dr�ver
Output (Max�mum 10mA, 17VZ )
Steam Output(ESM-9945) : Relay (5A@250VV at res�st�ve load) or opt�onal
SSR Dr�ver Output (Max�mum 10mA, 17VZ )
Bes�des these, there �s an �nternal buzzer for vo�ced warn�ng.
SPECIFICATIONS
INPUT
Process Input: TC/RTD
Thermocouple (TC): J, K, R and S (IEC584.1)(ITS90)
Thermores�stance (RTD): 2 or 3 w�re Pt100 ( IEC 751) (ITS90)
Measurement Range: Please refer to parameter �n parameters sect�on.
Accuracy: ± 0.25% of scale for thermocouple and thermores�stance.
Cold Junct�on Compensat�on: Automat�cally ±0.1°C/1°C
L�ne Compensat�on: Max�mum 10 Ohm
Sensor Break Protect�on: Upscale
Sampl�ng Cycle: 0.1 second
CONTROL
Control Forms: ON/OFF, P, PI, PD veya PID (Control form can be
programmed by the user.)
SUPPLY VOLTAGE
230VV (±15%) 50/60Hz - 3VA
115VV (±15%) 50/60Hz - 3VA
24VV (±15%) 50/60Hz - 3VA
(Must be determ�ned �n order.)
ENVIRONMENTAL RATINGS and PHYSICAL SPECIFICATIONS
Operat�ng Temperature: 0...50ºC
Hum�d�ty : 0-90%RH (none condens�ng)
Protect�on Class: IP65 at front , IP20 at rear
We�ght: 370 gr.
D�mens�on: 96 x 96 mm, Depth: 100 mm
Panel CutOut: 92 x 92 mm
To reduce the effect of electr�cal no�se on dev�ce, low voltage l�ne (espec�ally sensor
�nput cables) w�r�ng must be separately from h�gh current and voltage l�ne. If
poss�ble, use sh�elded cable abd sh�eld must be connected to ground only one s�de.
Output-1
TC
PT-100
4
5
10
11 12
13
14
15
Output-2
7A@250VV 5A@250VV5A@250VV
6 7 8 9
D�g�tal Input
Output-3
NCCNO
CNO CNO
ESM-9945-N
CAT II
O2
(T�me End
Output)
O1
(Temperature Control
Output)
Supply
Voltage
Sw�tch
N
Supply
Voltage
L
1A T
S�gorta
O3
(Steam
Output)
Cover
Sw�tch
Temperature
Sensor Input
Output-1
TC
PT-100
4
5
10
11 12
13
14
15
Output-2
7A@250VV 5A@250VV
6 7 8 9
D�g�tal Input
NCCNO
CNO
ESM-9944-N
CAT II
O2
(T�me End
Output)
O1
(Temperature Control
Output)
Supply
Voltage
Sw�tch
N
Supply
Voltage
L
1A T
S�gorta
Cover
Sw�tch
Temperature
Sensor Input
Instruct�on Manual. ENG ESM-994X-N 01 V02 02/18
1- Before mount�ng the dev�ce �n your panel, make
sure that the cutouts �s of the r�ght s�ze.
2- Check front panel gasket pos�t�on.
3- Insert the dev�ce through the cutout. If the
mount�ng clamps are on the un�t, put out them before
�nsert�ng the un�t to the panel.
4- Insert the mount�ng clamps to the two of
des�gnated holes that located on four s�des of dev�ce.
5- Drag the mount�ng clamps �n d�rect�on 5 unt�l the
dev�ce completely �mmob�le w�th�n the panel.
6- In order to remove dev�ce push on the mount�ng
clamp as shown w�th arrow 6 and pull back.
3
2
1
4
5
Access the Parameters
SET
+
°C
°F
P
O1
O2
++
Press encoder
button dur�ng 10 seconds.
Ma�n Screen
SET
+
°C
°F
P
O1
O2
++
Press encoder
button dur�ng 10 seconds.
Ma�n Screen
SET
If no pr�vacy lock �dent�f�cat�on
Parameters Screen w�ll be
observed. If pr�vacy lock �s
�dent�f�ed, w�ll be observed.
Press encoder button to access
Password Screen.
+
°C
°F
P
O1
O2
++
Enter the password using
encoder button. Turn left
encoder button to decrease or
turn right to increase value.
Approve password using
encoder button.
+
°C
°F
P
O1
O2
++
Password Screen
If Parameters Screen is
active, "P" led blinks. To
observe previous parameter,
turn encoder button left. To
observe next parameter, turn
encoder button right. Press
encoder button to observe
parameter value.
+
°C
°F
P
O1
O2
++
Parameters Screen