5. Changing and Saving Temperature and Humidity Set Value
5.1 Changing and Saving Humidity Set Value
Main Operating Screen
When SET button pressed ‘’S’’ led will
be active and temperature set value will
be displayed.
Temperature Set Value Screen
Temperature set value can
be changed with increment
and decrement buttons.
When SET button pressed
temperature set value can be saved.
Goes Humidity SET
value screen.
Temperature set value parameter ( Default =50 )
Temperature set value, can be programmed between minimum temperature set value and
maximum temperature set value .
°C
When SET button pressed
set value can be saved.
Humidity
Goes back to main operation screen.
Main Operating Screen
Humidity Set Value Screen
If no operation is performed in Humidity set value changing mode and temperature set value
changing mode for 20 seconds, device turns to main operation screen automatically.
i
Humidity Set Value Screen
8
Nem Set Parametresi (Default = 60%)
Humidity set value, can be programmed between minimum Humidity set value and maximum
temperature set value .
Temperature Set Value Screen
Humidity Set Value Screen
Humidity set value can be
changed with increment
and decrement buttons.