Instructions

16
All order information of ESM-3711HN Heating Controller are given on the table at above. User may
form appropriate device configuration from information and codes that at the table and convert it to the
ordering codes. Firstly, supply voltage then other specifications must be determined. Please fill the order
code blanks according to your needs. Please contact us, if your needs are out of the standards.
V
Z
Vac,
Vdc
Vdc or Vac
can be applied
Þ
Þ
ÞW
c
11.Ordering Information
Note-1:If input type is selected PTC or NTC (BC= 12, 18), Temperature sensor is given with the
device.For this reason, if input type is selected as PTC,sensor type (V = 0,1 or 2) or if input type is
selected as NTC, sensor type (V = 0,3 or 4) must be declared in ordering information.
ABCD E FGHI /
/
U
VWZ/
/
0100
1
Relay Output (16(8) A@250 V ,at resistive Load, 1 NO )V
Output-1
E
Supply VoltageA
Input Type
BC
Scale(°C)
ESM-3711HN
4
-50°C/-58°F ; 150°C/302°F
12
PTC (Not-1)
Temp. Sensor which is given with ESM-3711HN
V
0
None
3
NTC-M5L20.K1.5 (NTC Sensor, thermoplastic moulded with 1.5 m cable
for cooling application)
4
NTC-M6L50.K1.5 (NTC Sensor, stainless steel housing with 1.5 m cable
for cooling application)
9
Customer
115V ( %15) 50/60Hz - 1.5VAV ±
5
230V ( %15) 50/60Hz - 1.5VAV ±
00 00
8
10 - 30 V Z
-50°C/-58°F ; 100°C/212°F
18
NTC (Not-1)
1
PTC-M6L40.K1.5 (PTC Air Probe 1.5 mt Silicon Cable)
2
PTCS-M6L30.K1.5.1/8” (PTC Liquid Probe 1.5 mt Silicon Cable)
(77x35 DIN Sizes)
10.Optional Accessories
RS-485 Communication Interface
1.RS-485 Module
2.PROKEY Programming Module
The device is programmed(Upload or
Download) by using the parameters.
0°C/32°F ; 800°C/1472°F
05
J ,Fe CuNi IEC584.1(ITS90)
0°C/32°F ; 999°C/1830°F
10
K ,NiCr Ni IEC584.1(ITS90)
-50°C/-58°F ; 400°C/752°F
11
PT 100, IEC751(ITS90)
-19.9°C/-4°F ; 99.9°C/212°F
09
PT 100, IEC751(ITS90
-50°C/-58°F ; 400°C/752°F
14
PT 1000, IEC751(ITS90)
-19.9°C/-4°F ; 99.9°C/212°F
13
PT 1000, IEC751(ITS90
3
24V ( %15) 50/60Hz - 1.5VAV ±
2
SSR Driver Maximum 20m, Maximum 17VOutput ( )Z
2
24V ( %15) 50/60Hz - 1.5VAW ±
Your Technology Partner
www.emkoelektronik.com.tr
Thank you very much for your preference to
use Emko Elektronik products, please visit our
web page to download detailed user manual.
1- Screen Blinking
Sensor failure . Sensor connection is wrong or there is no sensor connection. If buzzer function
selection parameter is 3 or 4, internal buzzer starts to operate.
9. Failure Messages in ESM-3711HN Heating Controller
Example : If alarm function selection parameter in programming section is 1 (Absolute Alarm)
and maximum alarm parameter is 50 When temperature is above 50 °C, value on the screen
starts to blink. Also buzzer function selection parameter is 2 or 4, then internal buzzer is on.
2- Main Screen Value is Blinking.
ü
ENGLISH