User manual
4.4 Programming Mode Parameter List
Minimum Set Value Parameter ( Default = Input Type Minimum Scale )
Set value can not be lower than this value.
This parameter value can be adjusted from minimum value of device scale to
maximum set value parameter
Maximum Set Value Parameter ( Default = Input Type Maximum Scale )
Set value can not be greater than this value.
This parameter value can be adjusted from minimum set value parameter to
maximum value of the device scale
Hysteresis Parameter for Output ( Default = 0 )
From 0 to 100 °C for TC Type devices,
From 0 to 100 °C for PT-100 (-50°C , 400°C) and PT-1000 (-50°C , 400°C) ,
From 0.0 to 10.0 °C for PT-100 (-19.9°C, 99.9°C) and PT-1000 (-19.9°C, 99.9°C)
From 0 to 20 °C for PTC (-50°C, 150°C) ,
From 0.0 to 10.0 °C PTC (-19.9°C, 99.9°C)
Process Offset Parameter ( Default = 0 )
From -100 to 100°C for TC Type devices,
From -100 to 100°C for PT-100 (-50°C , 400°C) and PT-1000 (-50°C , 400°C),
From -10.0 to 10.0°C for PT-100 (-19.9°C, 99.9°C) and PT-1000 (-19.9°C, 99.9°C),
From -20 to 20°C for PTC (-50°C, 150°C),
From -10.0 to 10.0°C for PTC (-19.9°C, 99.9°C)
In ON/OFF control algorithm, temperature
value is tried to keep equal to set value by
opening or closing the last control element.
ON/OFF controlled system, temperature
value oscillates continuously. Temperature
value’s oscillation period or amplitude
around set value changes according to
controlled system. For reducing oscillation
period of temperature value, a threshold
zone is formed below or around set value
and this zone is named hysteresis.
Temperature Control Delay at Power On
It can be adjusted from 0 to 99 minutes.
( Default = 0 )
Cooking Time (Timer) Parameter
It can be adjusted from 1 to 999 minutes. When it is 1, can be observed by
pressing decrement button on the display. So Manual Control is selected. In Manual
control, user can start and stop temperature controlling with cooking ON/OFF button
or .
( Default = 45 )
cooking time start/stop input
21
ON
OFF
Temperature
Temperature
Control Output
Set
HSt
Time
HSt
Time
Selection of Temperature Control and Starting Cooking Time (Timer)
Parameter ( Default = 0 )
Temperature control and cooking time (Timer) starts at power on
Temperature control starts at power on. Cooking time (Timer) can be
started by pressing cooking ON/OFF button or when cooking time
start/stop input is getting closed condition.
Temperature control and cooking time (Timer) can be started by pressing
cooking ON/OFF button or when cooking time start/stop input is getting
closed condition.