User manual

i
13
Temperature Sensor Input is in CAT II class.
Supply Voltage Input
12V ( ± 15% ) 50/60Hz - 1.5
(It must be determined in order)
W VA
Relay or SSR
Driver Output
For SSr Output
3.2 Electrical Wiring Diagram
Electrical wiring of the device must be the same as ‘Electrical Wiring Diagram’
below to prevent damage to the process being controlled and personnel injury.
c
Supply Voltage Input
(It must be determined in order)
230 VA
115 VA
VA
VA
V ( ± 15% ) 50/60 Hz - 1.5
V ( ± 15% ) 50/60 Hz - 1.5
24 V ( ± 15% ) 50/60 Hz - 1.5
24 V ( -15%,10% ) 50/60 Hz - 1.5
V
V
V
W
Temperature Sensor Input
(TC, PTC, PT-100 or
PT-1000)
a
CAT II
P/N : 711-HESM-3
Yc
OUTPUT
NO NCC
10 A@250 V V
TC
PTC, PT-100
PT-1000
12 3 456789101112
(+)
(-)
L N L(+) N(-)
DIGITAL
INPUT
Cooking Time(Timer)
Start/Stop Input