User manual

6.ChangingandSavingTemperatureSetValue
MainOperationScreen
WhenSET buttonpressed‘’S’’ ledwill
beactiveandtemperaturesetvaluewill
bedisplayed.
SETValueScreen
Temperaturesetvaluecan
bechangedwithincrement
anddecrementbuttons.
WhenENTER buttonpressed
temperaturesetvaluecanbesaved.
‘’S’’ willbeinactiveandgoesbackto
mainoperationscreen.
MainOperationScreen
Temperaturesetvalueparameter(Default=10)MODBUS ADDRESS:40001
Temperaturesetvalue,canbeprogrammedbetweenminimumtemperaturesetvalueand
maximumtemperaturesetvalue.
4.2DeviceLabelandConnectionDiagram
4.ElectricalWiringDiagram
4.1SupplyVoltageInputConnectionoftheDevice
Note-1 : External fuse is recommended.
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While
installing the unit, supply voltage range must be controlled
and appropriate supply voltage must be applied to the unit.
c
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
important in electrical connection.
External fuse that on power supply inputs must be on
phase connection.
External fuse that on power supply inputs must be on (+)
connection.
V
Z
c
230VV CONNECTION DIAGRAM
5.FrontPanelDefinitionand AccessingtotheMenus
BUTTON DEFINITIONS
LED DEFINITIONS
1. Increment Button :
2. Decrement, Silencing Buzzer and Downloading to Prokey Button :
3. Set Button :
4. Cooking Button :
7.Alarm led :
8.Celcius led :
9.Fahrenheit led :
10.Set led :
11.Program led :
** It is used to increase the value in the Set screen and Programming mode.
** It is used to decrease the value in the Set screen and Programming mode.
** It is used to silence the buzzer.
** If Prc = 0, it is used to download from device to prokey.
** In the main operation screen; if this button pressed, set value will be displayed. Value can be
changed using increment and decrement buttons. When Enter button pressed, value is saved
and returns back to main operating screen.
** To access the programming screen; in the main operation screen, press this button for 5
seconds.
** It is used to saving value in the Set screen and programming screen.
** In the main operation screen; if this button pressed, cooking time value will be displayed.
**In the main operation screen; if this button pressed for 3 seconds, cooking time starts.
** This led indicates that cooking time is active.
** Blinks (5 Hz) while entering Cooking time value.
** It is active when low alarm and high alarm statuses.
** Indicates that device is in C mode.
** Indicates that device is in F mode.
** Indicates that device is in Set value changing mode.
**Blinks in programming mode .
o
o
5. Cooking Time led :
6. Output led :
** Thisledindicatesthatheatingcontrolisselectedandprocessoutputrelayisactive.
SensorOffsetParameter(Default=0)MODBUS ADDRESS:40007
from-20to20°CforNTC(-50°C,100°C)orPTC(-50°C,150°C)orJ Type TC(0°C,800°C)
orJ Type TC(0°C,1000°C)orPT-100(-50°C,400°C)orPT-1000(-50°C,150°C)or
PT-100(-20°C,100°C),
from -36 to 36 °F for NTC(-58°F, 212°F) or PTC(-58°F, 302°F) or J Type TC (32°F,1472°F) or
or K Type TC (32°F,1830°F) or PT-100(-58°F, 752°F) or PT-1000(-58°F, 752°F) or
PT-100(-4°F, 212°F),
from -10.0 to 10.0°C for NTC(-50.0°C,100.0°C) or PTC(-50.0°C,150.0°C) or
PT-100 (-19.9°C,99.9°C),
from -18.0 to 18.0°F for NTC(-58.0°F,212.0°F) or PTC(-58.0°F,302.0°F) or
PT-100 (-4.0°F,212.0°F),
MODBUS ADDRESS:30001TemperatureValue
MODBUS ADDRESS:30002LedStatus:0.bit CLed,6.bitOutputLed,7.bit AlarmLed,
13.bitProgramLed,14.bitSetLed
MODBUS ADDRESS:30003DeviceStatus:0.bit AlarmStatus
1.bitBuzzerStatus2.bitSensorBreakStatus
MODBUS ADDRESS:30004OutputStatus0.BitOutput
MODBUS ADDRESS:30005DeviceTypeandDeviceVersion
o
A
6.3 Modbus Adresses of Device Status Parameters (Read Input Register)
5 6 9 10
121187
1.Switchoffthedevice.
2.PutinPROKEY thenenergizethedevice.
3.Whenthedeviceisenergized,theparametervaluesinPROKEY,startdownloadingtothedevice
automatically. Atfirst,messageisshownonthedisplay,whenloadinghasfinished,
messageisshown.
4.After10secondsdevicestartstooperatewithnewparametervalues.
5.RemovethePROKEY.
1-Before mounting the device in your panel,
make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and make
the unit completely immobile within the panel
1-Pull mounting clamps from left and right fixing
sockets.
2-Pull the unit through the front side of the panel
Before starting to remove the unit from
panel, power off the unit and the related
system.
c
2.3PanelMounting
2.4RemovingfromthePanel
3.UsingProkey
DOWNLOADINGFROMDEVICETOPROKEY
1.Thedeviceisprogrammedbyusingtheparameters.
2.EnergizethedevicethenputinPROKEY andpressbutton.Messageisshownonthe
display.Whentheloadinghasfinished,messageisshown.
3.Pressanybuttontoturnbacktomainoperationscreen.
4.RemovethePROKEY.
DOWNLOADINGFROMPROKEY TODEVICE
NOTE:messageisshownwhenanerroroccurswhileprogramming.Ifyouwanttoreload,put
inPROKEY andpressbutton.Ifyouwanttoquit,removePROKEY andpressbutton. The
devicewillturnbacktomainoperationscreen.
NOTE:messageisshownwhenanerroroccurswhileprogramming.Ifyouwanttoreload,
switchoffthedeviceandputinPROKEY thenenergizethedevice.Ifyouwanttoquitremove
PROKEY andpressbutton. Thedevicewillturnbacktomainoperationscreen.
TOUSEPROKEY,VALUEOFTHEPrCPARAMETERMUSTBE‘0’.
IFPrC=1 ANDBUTTONISPRESSEDMESSAGEWILL BESHOWN.10s.LATER
DEVICETURNSBACKTOTHEMAINOPERATIONSCREENOR YOUCANPRESSSET
BUTTONTOTURNBACKTOMAINOPERATIONSCREEN.
6.2ProgrammingModeParameterList
Hysteresis Parameter for Compressor Output ( Default = 1 )
MODBUS ADDRESS:40004
from 1 to 20°C for NTC (-50°C, 100°C) or PTC (-50°C, 150°C) or J Type TC ( 0°C, 800°C ) or
K TypeTC ( 0°C, 1000°C or PT-100 Type ( -50°C,400°C ) or PT-1000 Type ( -50°C,400°C )
or PT-100 Type ( -20°C,100°C ),
from 1 to 36°F for NTC (-58°F, 212°F) or PTC (-58°F, 302°F) or J Type TC (32°F,1472°F)or
K Type TC (32°F,1830°F) or PT-100 Type (-58°F,752°F) or PT-1000 Type (-58°F,752°F)
or PT-100 Type (-4°F,212°F)
from 0.1 to 10.0°C for NTC(-50.0°C,100.0°C) or PTC (-50.0°C,150.0°C)
or PT-100 (-19.9°C,99.9°C),
from 0.1 to 18.0°F for NTC (-58.0°F,212.0°F) or PTC (-58.0°F,302.0°F) or
PT-100 (-4.0°F,212.0°F),
In ON/OFF control algorithm, temperature
value is tried to keep equal to set value by
opening or closing the last control element.
ON/OFF controlled system, temperature
value oscillates continuously. Temperature
value’s oscillation period or amplitude around
set value changes according to controlled
system. For reducing oscillation period of
temperature value, a threshold zone is formed
below or around set value and this zone is
named hysteresis.
ON
OFF
Temperature
Control
Output
Set
HSt
Time
HSt
Time
Minimum Temperature Set Value Parameter (Default = Minimum Value of Device
Scale ) MODBUS ADDRESS:40005
Temperature set value can not be lower than this value.
This parameter value can be adjusted from minimum value of device scale to maximum
temperature set value parameter
Maximum Temperature Set Value Parameter (Default = Maximum Value of Device
Scale ) MODBUS ADDRESS:40006
Temperature set value can not be bigger than this value.
This parameter value can be adjusted from minimum temperature set value parameter
to maximum value of the device scale
Decimal Seperator Enabling Parameter ( Default = 0 ) MODBUS ADDRESS:40003
Disable.
Enable.
Temperature Unit Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40002
°C selected.
°F selected.
Buzzerisactiveduringthistime
Whenthisparameteris1,ifdecrementbuttonispressed,isobserved.Inthis
conditionbuzzerisactivetillbuzzersilencebuttonispressed.
(Default=)MODBUS ADDRESS:40019
Ifbuzzerfunctionselectionparametervalue=0,thisparametercannotbe
observed.Buzzerstaysactiveduringthistime.Itcanbeadjustedfrom1to99minutes
Programming Section Accessing Password 23
.
( Default = 0 ) MODBUS ADDRESS: 400
It is used for accessing to the programming section. It can be adjusted from 0 to 9999. If it is
selected 0, password will not be asked
PROKEY communication selected.
Communication Mode Selection Parameter 21( Default = 0 ) MODBUS ADDRESS: 400
RS-485 communication selected.
Slave ID Parameter 22( Default = 1 ) MODBUS ADDRESS=400
Device communication address parameter (1 to 247).
PowerSupplyConnection
c
a
EXTERNAL
FUSE
(1A T)
Note-1
Supply
Switch
Supply Voltage
4
5
L
N
Note: If sensor input type is selected J, K, PT-100 or PT-1000 (BC = 05,10,11 or 14) parameter
becomes passive and can not be changed.
SETValueScreen
230V ( %15) 50/60Hz ,
115V ( %15) 50/60Hz,
24V ( %15) 50/60Hz ,
24V ( %15) 50/60Hz ,
Z
V
V
V
W
±
±
±
±
10..30 V - 1.5 W
Mustbedeterminedinorder.
RelayorSSROutput
21 4 5 7 8
P/N: ESM-3711HN
L
N
a
SupplyVoltageInput
TemperatureSensor Input
TC,NTC,PTC,PT-100
orPT-1000
230V ( %15) 50/60Hz
115V ( %15) 50/60Hz
24V ( %15) 50/60Hz
24V ( %15) 50/60Hz
Z
V
V
V
W
±
±
±
±
10...30 V
Must be determined in order.
3
(+)
(-)
ForSSROutput
(+)
(-)
7
9
10
5
8
6
ü
1
2
3
4
11
3
1
3
2
2
1
L
N
16A FUSE
LOAD
6.1ChangingandSavingCookýngTime(Timer)ParameterValue
Whendefrostbuttonispressed,
cookingtimeisshownandcookingtime
ledstartstofastblink(5Hz).
Presssetbuttonforsavingthe
cookingtime
Cookingtimeissaved,cookingtimeled
activeledlightsoff,mainoperationscreen
isshown.
MainOperatingScreen
CookingTime(Timer)ValueScreen
If no operation is performed in defrost time set value changing mode and temperature set
value changing mode for 20 seconds, device turns to main operation screen automatically.
i
Changethecookingtimewith
incrementanddecrement
buttons.
MainOperatingScreen
CookingTime(Timer)ValueScreen
Temperature Control Delay at Power On
It can be adjusted from 0 to 99 minutes.
( Default = 0 ) MODBUS ADRES : 40008
Cooking Time (Timer) Parameter
It can be adjusted from 1 to 999 minutes. When it is 1, can be observed by pressing
decrement button on the display. So Manual Control is selected. In Manual control, user can
start and stop temperature controlling with cooking ON/OFF button or
.
( Default = 45 ) MODBUS ADDRESS : 40009
cooking time
start/stop input
Selection of Temperature Control and Starting Cooking Time (Timer) Parameter
(Default = 0 ) MODBUS ADDRESS : 40010
Temperature control and cooking time (Timer) starts at power on.
Temperature control starts at power on. Cooking time (Timer) can be started by
pressing cooking ON/OFF button or when cooking time start/stop input is getting
closed condition.
Temperature control and cooking time (Timer) can be started by pressing cooking
ON/OFF button or when cooking time start/stop input is getting closed condition.
Temperature Controlling Continuity Selection Parameter
Temperature controlling can be continues or stopped according to the selection. This
parameter can be observed if cooking time (Timer) is 1³
( Default = 0 )
MODBUS ADDRESS : 40012
Cooking Time Starting Conditions Parameter
This parameter can be observed if cooking time (Timer) is 1.³
( Default = 0 )
MODBUS ADDRESS: 40011
Minimum Alarm Parameter
It can be adjusted from minimum scale of the device to maximum alarm value .
( Default = Input Type Minimum Scale )
MODBUSS ADDRESS : 40014
Temperature Alarm Function Selection Parameter ( Default = 0 )
MODBUS ADDRESS : 40013
Maximum Alarm Parameter (Default = Input Type Maximum Scale)
It can be adjusted from minimum alarm value to maximum scale of the device.
MODBUS ADDRESS : 40015
Interrupted Operation : Temperature control starts after temperature control
starting delay at power on is expired. Temperature control can be stopped
at the end of the cooking time (Timer) or by pressing cooking ON/OFF button or
when Temperature control
does not start till cooking ON/OFF button is pressed again or when
cooking time start/stop input is getting open condition.
cooking time
start/stop input is getting closed condition again.
Continuous Operation : Temperature control starts after the temperature
control starting delay at power on is expired and continues. If buzzer
function selection parameter Is 1 or 5, at the end of the cooking time, (Timer)
internal buzzer operates to indicate cooking time has finished.
Cooking time (Timer) is started when temperature reaches to the process set
value after pressing cooking ON/OFF button or when cooking time start/stop
input is getting closed condition.
Cooking time (Timer) is started with cooking ON/OFF button or when cooking
time start/stop input is getting closed condition.
Alarm Delay Parameter ( Default = 0 ) MODBUS ADDRESS : 40016
If an alarm occurs, delay can be defined with this parameter. It can be adjusted from 0
to 99 minutes.
Relative alarm is selected. Alarm operates according to the set value.
If temperature is below (Set - ) or above ( Set + ), alarm occurs.
Alarm function is inactive.
Absolute alarm is selected. If temperature lower than and higher
than , then alarm is on.
Temperature Alarm Delay After Power On Parameter
When power is first applied to the device, this time delay must be expired for activation of
temperature alarm. It can be adjusted from 0 to 99 minutes.
( Default = 0 )
MODBUS ADDRESS:40017
Buzer Fonksiyon Seçimi Parametresi ( Default = 1 ) MODBUS ADDRESS:40018
Buzzer is inactive.
Buzzer is active at the end of the cooking time.
Buzzer is active if an alarm occurs.
Buzzer is active during sensor failures.
Buzzer is active at the end of the cooking time, alarm or sensor failures.
Hst
= =
°C
Hst
°C
Hst
Hst
0 1
=
=
0
1
1- When cooking time parameter 1, if selection of temperature control and starting the
cooking time parameter = 0 ( Temperature control and cooking time starts at power on) is
selected;
³
2- When cooking time parameter 1, if selection of temperature control and starting the
cooking time parameter = 1 ( Temperature control starts at power on. Cooking time (Timer)
can be started by pressing cooking ON/OFF button or when
is selected;
³
cooking time start/stop input is
getting closed condition)
6.5OperationGraphicsofESM3711HNHeatingController
TemperatureControl
is Active
Temperature
Control
is Active
Temperature
Control
is Active
Power
Cooking
Time
Active
Led
Process
Output
Process
Set
(ContinuousOperation)
Power
(Interrupted )Operation
Buzzeris
Active
Cooking
Buttonstarts
time
Time
Time
Time
Time
=1=1
Buzzeris
Active
Cooking
Time
Active
Led
Process
Set
Process
Output
Time
Time
Time
Time
Cooking
Buttonstarts
time
(ContinuousOperation) (Interrupted )Operation
°C
Power
Cooking
Time
Active
Led
Process
Output
Process
Set
°C
Power
Cooking
Time
Active
Led
Process
Output
Process
Set
TemperatureControl
is Active
Temperature
Control
is Active
Temperature
Control
is Active
=1
Time
Time
Time
Time
Cooking
Buttonstarts
time
Cooking
Buttonstarts
time
Buzzeris
Active
=1
Buzzeris
Active
Cooking
Buttonstarts
time
Cooking
Buttonstarts
time
Time
Time
Time
Time
ü
ü
Button Protection Parameter 20( Default = 0 ) MODBUS ADDRESS: 400
There is no protection
Cooking time(Timer) can not be changed. Cooking ON/OFF operation is not
performed.
SET value can not be changed.
Cooking time (Timer) and set value can not be changed. Cooking ON/OFF
operation is not performed.
Cooking time (Timer) and set value can not be changed. Cooking ON/OFF
operation is performed when button is pressed.
6
CookingTime(Timer)
Start/StopInput
ü
ü
ü
ü
ü
ü