Instructions

10
Cooking Time (Timer) Parameter
It can be adjusted from 1 to 999 minutes. When it is 1, can be observed by pressing
decrement button on the display. So Manual Control is selected. In Manual control, user can
start and stop temperature controlling with cooking ON/OFF button or
.
( Default = 45 ) MODBUS ADDRESS : 40009
cooking time
start/stop input
Selection of Temperature Control and Starting Cooking Time (Timer) Parameter
(Default = 0 ) MODBUS ADDRESS : 40010
Temperature control and cooking time (Timer)starts at power on.
Temperature control starts at power on. Cooking time (Timer) can be started by
pressing cooking ON/OFF button or when cooking time start/stop input is getting
closed condition.
Temperature control and cooking time (Timer) can be started by pressing cooking
ON/OFF button or when cooking time start/stop input is getting closed condition.
Temperature Controlling Continuity Selection Parameter
Temperature controlling can be continues or stopped according to the selection. This
parameter can be observed if cooking time (Timer) is 1³
( Default = 0 )
MODBUSADDRESS : 40012
Cooking Time Starting Conditions Parameter
This parameter can be observed if cooking time (Timer) is 1.³
( Default = 0 )
MODBUS ADDRESS: 40011
MinimumAlarm Parameter
It can be adjusted from minimum scale of the device to maximum alarm value .
( Default = Input TypeMinimum Scale )
MODBUSSADDRESS : 40014
Temperature Alarm Function Selection Parameter ( Default = 0 )
MODBUSADDRESS : 40013
MaximumAlarm Parameter (Default = Input Type Maximum Scale)
It can be adjusted from minimum alarm value to maximum scale of the device.
MODBUSADDRESS : 40015
Interrupted Operation : Temperature control starts after temperature control
starting delay at power on is expired. Temperature control can be stopped
at the end of the cooking time (Timer) or by pressing cooking ON/OFF button or
when Temperature control
does not start till cooking ON/OFF button is pressed again or when
cooking time start/stop input is getting open condition.
cooking time
start/stop input is getting closed condition again.
Continuous Operation : Temperature control starts after the temperature
control starting delay at power on is expired and continues. If buzzer
function selection parameter Is 1 or 5, at the end of the cooking time, (Timer)
internal buzzer operates to indicate cooking time has finished.
Cooking time (Timer) is started when temperature reaches to the process set
value after pressing cooking ON/OFF button or when cooking time start/stop
input is getting closed condition.
Cooking time (Timer) is started with cooking ON/OFF button or when cooking
time start/stop input is getting closed condition.
Alarm Delay Parameter ( Default = 0 ) MODBUS ADDRESS : 40016
If an alarm occurs, delay can be defined with this parameter. It can be adjusted from 0
to 99 minutes.
Relative alarm is selected.Alarm operates according to the set value.
If temperature is below (Set - )or above ( Set + ), alarm occurs.
Alarm function is inactive.
Absolute alarm is selected. If temperature lower than and higher
than ,then alarm is on.
ENGLISH