Datasheet

www.emkoelektronik.com.tr
PID - HOT RUNNER
CONTROL UNIT
Activate 2nd Set Value
by front panel
Digital or RS-485 input for activate
the 2nd Set Value (Optional)
RS-485 ModBus
Digital Input
220Vac
B-
A+
TC
Communication (E)
485485
DIDI
C
C
NO NO
NO
2R2R
1R1R
Or
or
Input
Power Supply
(B)
High Resolution
Sensitive PID control
TC (J,K,R,S,T Input Types) and
RTD inputs selectable by parameter
Low Power Consumption, Energy
saving and Environmentally Friendly
with 2VA
Saving and Recovery
of user parameters
Return to Factory Settings
RS-485 Modbus (RTU)
communication option
Password protection for programming mode
Programmable ON-OFF,
P, PI, PD, PID control forms
Adaptation of PID Coefficients to the system
with Self-Tune operation (Step ResponseTuning)
Selectable Alarm Functions
for alarm outputs
Operation type selection with hysteresis
Selectable temperature offset value
Minimum pulling time adjustment
for control outputs
STANDARD FEATURES
3 digits Process (PV) and 4 digits Set (SV) display
Process input ( TC )
Selectable heating and cooling function
Programmable
ON/OFF, P, PI, PD or PID (Programmable)
Relay (5A@250V ~ at Resistive Load)
----
___
Or SSR Driver Output (Maximum 10mA, Max. 12V )
TECHNICIAL SPECIFICATIONS
Specifications
Output
Environmental
Conditions
Process Input
Measurement Range
Accuracy
Cold Junction
Compensation
Line Compensation
Sensor Break Protection
Sampling Cycle
Input Filter
Control Form
Process Output
Alarm Outputs
Operation Temperature
Humidity
Protection Class
Weight
Dimension
Depth
Panel Cut-Out
0...50ºC
0-90%RH (None condensing)
Ip65 in front, Ip20 in rear
150 gr.
48 x48 mm
86,5 mm
46 x46 mm
Relay (5A@250V ~ at Resistive Load)
Please refer to process input type selection
in process menu parameter section.
± 0,25 of scale for thermocouple and thermoresistance
Automatically. ±0.1°C/1°C
Maximum 10 Ohm
Upscale
0,1 second
(TC): J, K, R, S and T (IEC584.1)(ITS90)
SSR Driver
Output
Output-2 (D)
Output-1 (C)
USAGE AREAS
All Applications Requiring Temperature Control
PLASTIC