Technical data
3 | ENGLISH
Caution! If you operate devices that do not correspond to the technical specifications
(see technical data), you can damage the connected devices and the radio receiver.
• Only connect luminaires to the dimmer.
• Do not connect luminaires with energysaving lamp(s).
• Do not connect combinations of electronic and conventional transformers
• Only dimmable transformers may be connected.
• Connecting combinations of transformers and ohmic loads, incandescent lamps,
230 V halogen lamps is only permitted if the power of the ohmic load is max. 30%
of the entire connected load.
Note: Do not use dimmers on socket-outlets! The risk of overloading and the risk of
unsuitable appliances being connected is too high.
Note: If the load on connected wound transformers is too low, the dimmer may
malfunction during operation. The load on the transformer should therefore be at least
40% of the nominal power of the transformer.
Note: An excessive load will trigger the dimmer's overload protection. Reduce the
connected load and then switch the dimmer on again.
Note: If you install several dimmers next to each other, reduce the maximum load
allowed by 20% because of the reduced heat dissipation.
Figure 1 – EM6610 connectors