Specifications

4 | ENGLISH
3.0 Installing the mini switch
3.1 Installing the mini switch into a junction box
Warning!
If you do not have enough electrical skills, do not continue and let a certified
electrician do the job for you. Otherwise you might get injured and/or electrocuted.
If you do have the skills, be very careful. Take notice of the following
Disable the mains of your house by turning of the main switch, before you
continue. Otherwise you might get injured and/or electrocuted.
In some older houses the colors of the wiring can be different. In some situations
not all wires are available and you might need to pull an extra wire from the
nearest distribution box.
Do not install the mini switch near combustible substances or any source of heat,
e.g. fires, radiators, boilers etc.
Do not install the mini switch facing direct sunlight, humid or dusty places
Below a technical drawing of the connectors on the EM6556:
Figure 2, technical drawing
1. Take the mini switch out of the packaging.
2. Open the junction box where you want to install the mini switch.
3. Check if the power is really switched off (for example by using a voltage tester)
4. Connect the blue neutral wire of the lamp with the left N output of the mini switch
and tighten the screw.
5. Connect the blue neutral wire of the mains with the N input (middle) of the mini
switch and tighten the screw.