Specifications
Emhart Teknologies - 50 Shelton Technology Center, Shelton CT 06484 - Tel. (203) 924-9341 - Fax (800) 225-5614  Page 7 
1.  REMOVE NOSE HOUSING: 
Remove Nose Housing Assembly by grasping the 
Nose Housing Nut by hand and rotate the entire 
assembly counterclockwise until the threads are 
fully disengaged. Tools are not required, however, 
flats are provided as back-up.  
Slide Nose Housing Assembly off the tool. 
2.  REMOVE JAW GUIDE TO ACCESS JAWS 
INTERNAL PARTS: 
Pull back the Collar to disengage the Collar teeth 
from the Jaw Guide teeth. 
Once the teeth are disengaged unscrew the Jaw 
Guide from the Pulling Head Adaptor. 
Remove jaws, jaw pusher, and jaw pusher spring for 
servicing. Tools are not required. 
3.  CLEAN PARTS: 
Clean jaws, jaw guide, jaw pusher, spring and 
thread area of the pulling head adaptor. Also be 
sure to clean the inside of the Nose Housing 
Assembly. A long narrow wire may be needed to 
loosen debris at the inside-front surface. 
4.  REASSEMBLY OF INTERNAL PARTS AND JAW 
GUIDE: 
Apply Lubriplate to jaws and to conical area of the jaw 
guide and Jaw Pusher. Place the Jaws and Jaw 
Pusher into the Jaw Guide and slide the Jaw Pusher 
Spring into the Pulling Head Adaptor. 
Apply a slight amount of Lubriplate
®
 130 AA to the 
Pulling Head Adaptor threads and Collar teeth. Screw 
the Jaw Guide onto the Pulling Head Adaptor until the 
teeth on the Collar causes the Jaw Guide to stop 
rotating. 
Do not pull the collar back and fully tighten jaw 
guide onto the pulling head adaptor. 
Apply jaw lube to the jaw area by submerging the 
assembled jaw guide into jaw lube about 1 in. (25mm). 
Make sure the MCS unit is turned off. 
5.  REINSTALL NOSE HOUSING ASSEMBLY: 
Slide the Nose Housing Assembly over the Pulling 
Head Adaptor. Hand tighten the Nose Housing Nut 
onto the Adaptor so that it squeezes snuggly against 
the Nose Housing Seal. 
Do not use a wrench to tighten the nose housing 
onto the tool. The wrench flats are only to assist 
removal of the nose housing when necessary.  
Check to make sure that there is sufficient squeeze on 
the Nose Housing Seal. There may be a loss of 
vacuum if the Nose Housing Seal is not fully engaged. 
Note: Turn off MCS unit while servicing tool to avoid sucking any oils or other fluids into the MCS unit.  
Front End Service 
For optimal tool performance, Front End maintenance should be performed regularly per the “Preventative Maintenance 
Schedule”.
Nose Housi
ng 
Assembly 
Nose Housing Nut
Adapter
To remove 
ONLY 
Collar 
Jaw 
Guide 
Jaw Guide 
Tooth
Collar teeth 