Installation

B165(rC) Page 3
Diagram #7
VOLUME CONTROL
OUTPUT TO JACK
INPUT
OUTPUT
TONE CONTROL
(PASSIVE)
SPC CONTROL OR
OTHER ACTIVE CONTROL
NOTE: REVERSED
INPUT CONNECTOR
VOLUME CONTROL
TONE CONTROL (ACTIVE VLPF)
OUTPUT TO JACK
INPUT
OUTPUT
INPUT
OUTPUT
SPC CONTROL OR
OTHER ACTIVE CONTROL
NOTE: REVERSED
INPUT CONNECTOR
NOTE: REVERSED
INPUT CONNECTOR
Daisy Chained Controls:
If you are going to “daisy-chain” your controls in a row, i.e. master volume, master tone
(either active or passive), and an SPC Control or other EMG Active control, you won’t
use the send and return feature, refer to Diagrams #7 and #8.
Install the 2 shunts on the bypass header, sending the pickup signals directly to the
switch terminals.
Diagram #7 has a master volume, passive tone control, and an SPC or any other
EMG Active control.
Diagram #8
Diagram #8 has a master volume control, but features two active tone
controls. This would be similar to an EMG-X Series wiring that doesn’t use
a passive tone control. Any EMG Active tone control could be used in either
tone control position, i.e. VLPF, SPC, RPC, or EXG, the choice is yours.
Notice the reversed input connectors on the Active controls!!