oA1 Second relay configuration (1-7) dEF = defrost; FAn: do not select it!; ALr: alarm; Lig: light;
AUS: Auxiliary relay; onF: always ON with controller ON; db =
neutral zone; cP2 = do not select it!; dEF2: do not select it!; HES:
night blind
AOP Alarm relay polarity Set if the alarm relay is open or closed when an alarm happens.
CL = terminals 1-7 closed during an alarm
oP = terminals 1-7 open during an alarm
DIGITAL INPUTS
i1P Digital input polarity (18-20) oP = the digital input is activated by opening the contact
CL = the digital input is activated by closing the contact
i1F Digital input configuration (18-20) dor = door switch function
dEF = activation of a defrost cycle
i2P
2
nd
digital input polarity (18-19)
oP = the digital input is activated by opening the contact
CL = the digital input is activated by closing the contact
i2F
2
nd
digital input configuration
(18-19)
EAL = external alarm: EA message is displayed; bAL = serious
alarm; CA message is displayed; PAL = pressure switch alarm,
CA message is displayed; dor = door switch function; dEF = ac-
tivation of a defrost cycle; ES = energy saving; AUS = auxiliary
relay activation with oA1 = AUS; Htr = kind of action inversion
(cooling – heating); FAn = fan; HdF = Holiday defrost (enable
only with RTC); onF = to switch the controller OFF
did With i2F = EAL or i2F = bAL: digital
input alarm delay (18-20)
(0 to 255 min)
Delay between the detection of the external alarm condition and
its signaling.
With i2F = PAL: time for pressure
switch function
(0 to 255 min)
Time interval to calculate the number of the pressure switch acti-
vation.
doA Door open signaling delay (0 to 255 min)
nPS Pressure switch number (0 to 15)
Number of activation of the pressure switch, during the did inter-
val, before signaling the alarm event (i2F= PAL). If the nPS ac-
tivation in the did time is reached, switch OFF and ON the
controller to restart normal regulation.
Odc Compressor status when open door no; FAn = normal; CPr, F_C = Compressor OFF
rrd Outputs restart after doA alarm no = outputs not affected by the doA alarm
yES = ou
tputs restart with the doA alarm
HES Temperature increase during the Energy
Saving cycle
(-30.0°C to 30.0°C)
Sets the increasing value of the setpoint during the Energy Saving
cycle.
TO SET CURRENT TIME AND WEEKLY HOLIDAYS (ONLY FOR MODELS WITH RTC)
Hur Current hour (0 to 23 hr) Sets the current hour.
Min Current minute (0 to 59 min) Sets the current minute.
dAY Current day (Sun to SAt) Sets the current day of the week.
Hd1 First weekly holiday (Sun to not used) Sets the first day of the week which follows the holiday times.
NOTE:
Hd1 can be set also as not used value.
Hd2 Second weekly holiday (Sun to not used) Sets the second day of the week which follows the holiday times.
NOTE:
Hd2 can be set also as not used value.