Monitor and respond to critical devices
intelligently
• See device status (Normal, In Alarm, Maintenance Mode, Not
Responding) on a graphical floor plan and in real time to get a
more comprehensive view of actual device health
• Configure data points for collection and assign data collection
intervals
• Categorize and visualize data via Configure, Control, Support and
Specification tabs
• Use Accelerated Polling to monitor trends during power outage
and when running on battery power for maintenance; compare
load with run time to provide additional measurement of load
percentage versus available battery run time
• Control and command other devices to perform actions using an
alarm as a trigger, minimizing need for personnel intervention
(i.e., high temperature); gather data from any device in the
system once alarm is triggered
• Real-time tracking of aisle temperature during extended power
outage via Cold Aisle Temperature Sensors and track aisle
temperature or evaluate high room temperature events
• Get notifications via SNMP, SMS or email and based on working
hours of facilities personnel so alarms are addressed to the right
person promptly; determine delivery based on notification states
(Success, Failed or Pending)
• Provide alarm attributes, filters, transitions, views (active and
audit/calendar) as well as actions (acknowledgment, escalation,
accelerations, etc.,); assign alarms and notification rules
according to user role
• Use logical operators (AND, OR, NOT) to create logic between
alarms so notifications are sent only after conditions of related
alarm are met; no notification sent if action is no longer needed
• Suppress alarms so users won’t need to spend time receiving
and checking notifications from devices that send erroneous,
intermittent alarms
• Use Summary View to see what alarm merits immediate
attention and to see alarms side-by-side to understand their
context, cause and relationship, if any
Track consumption in real time for better
efficiency
• Use the unified dashboard to see real-time data, energy usage
and operating efficiency together; key information helps
determine system peak performance, maximize energy usage
and minimize energy waste
• Customize dashboards so users can enter data manually if the
data center is not properly instrumented for measuring total
facility or IT load
• Gauge efficiency and comply with current and historical industry-
approved efficiency metrics (PUE and DCIE)
• Compute real-time power consumption (kW/hour) for a device
and determine ways to balance capacity and demand within the
data center
• Eliminate readings from one or more devices when making PUE
and DCIE calculations in a mixed-use (office space + data center)
data center facility
• Configure source and currency details that facilitate utility cost
calculations at the system and unit levels… so you can determine
actual costs, not just consumption
• Understand capacity usage to ensure business-critical services
are always up and running while lowering operating costs; roll
out measures to improve peak performance