10SensiTM Touch Wi-Fi Thermostat | MANUAL OPERATION GUIDE
Wiring terminals
TERMINAL OUTPUTS AND WIRING DIAGRAMS
Does wire color correspond to the thermostat terminals?
Wire color does not always correspond to the thermostat letters. A white wire may be attached to the “W”
terminal on the old thermostat, or it may be attached to a different terminal with a different letter. Be sure
to take a photo of the old thermostat that shows the wire colors and terminal letters before labeling and
removing any wires.
INSTALLATION
TERMINAL LABEL DEFINITION
RH* Power for heating, 24V
RC* Power for cooling, 24V
C** Common wire, 24V
G Indoor blower (fan)
Y First outdoor stage cooling on conventional systems or first heat and cool on heat pump
systems
Y2 Second outdoor stage cooling on conventional systems or second heat and cool on two stage
heat pump systems
W/E First indoor stage heat on conventional systems or first stage auxiliary/emergency heat on heat
pump systems
W2 Second indoor stage heat on conventional systems or second stage auxiliary/emergency heat on
heat pump systems
O/B Changeover (reversing valve) connection for heat pump or zone panel systems