Installation www.controltechniques.com 3
2 Installation
This section of the manual will cover basic installation
information.
2.1 Mechanical Installation
Please refer to the Installation Sheet that comes with the
SM-EZMotion module for details on installing the module
into the Unidrive SP.
2.2 Slot Selection
The SM-EZMotion module may be placed in any of the
three available option slots on the Unidrive SP. The user
must indicate which slot the SM-EZMotion module is fitted
in using PowerTools Pro configuration software. The
default slot number is Slot 3 in the configuration software.
2.3 Electrical Connections
The SM-EZMotion module has three separate terminal
blocks used to access the different features. Figure 2
shows a diagram of these connections.
Figure 2: Connection Diagram
The terminals are numbered from Terminal 1 on the left to
Terminal 7 on the right. The different terminal functions are
listed in the table below.
2.4 Digital I/O Connections
The SM-EZMotion module is equipped with 4 digital inputs
and 2 digital outputs. The I/O are electrically sourcing I/O.
All I/O utilize positive logic meaning that they are active
when a positive voltage is applied (10-30 VDC). See the
Specifications section at the back of the manual for more
detailed information on the digital I/O.
The digital I/O can be used to control different functions in
the SM-EZMotion module. The digital I/O on the
SM-EZMotion module are updated at the SM-EZMotion
Trajectory Update Rate. The Trajectory Update Rate can
be found on the Setup view in PowerTools Pro (see “Setup
View” on page 48 for more information on the Trajectory
Update Rate).
The digital I/O on the SM-EZMotion module are also
unique (as compared to Unidrive SP digital I/O and SM-I/O
Plus module I/O) because they can be used in the
SM-EZMotion module high speed capture process. Even
though they are only updated once every Trajectory
Update, the SM-EZMotion module processor knows when
they activate to within 1 microsecond. Therefore, when
Capture is used, they can be accurate to 1 microsecond
(see “Capture View” on page 59 for more information on
the SM-EZMotion module Capture object).
2.5 Connecting Motor Encoder
Feedback to the Unidrive SP
Figure 3 can be used to connect the encoder feedback
signals for various different motors to the Unidrive SP. For
further installation information, please refer to the Unidrive
SP User Guide.
Terminal # Function Description
1OV Common
OV Common connection for
digital I/O
2 Input1 Digital Input 1
3 Input2 Digital Input 2
4 Input3 Digital Input 3
5 Input4 Digital Input 4
6 Output1 Digital Output 1
7 Output 2 Digital Output 2
12
3
45
67