Installation guide

Installation Guide AMS Suite: Intelligent Device Manager
NOVEMBER 2013
13
Table 1: Upgrading from AMS Device Manager 10.x or later
Current
Setup
Desired 12.5 Setup
Server Plus Station Client SC Station
Server Plus
Station
Check in all calibration routes
Back up existing database (page 16)
Uninstall SNAP-ON applications, if
installed
2
Uninstall AMS Suite Calibration
Connector application, if installed
Uninstall T+H TACC components, if
installed (refer to TACC guides
downloaded from T+H)
Remove any configured HART Over
PROFIBUS and HART Over PROFIBUS
/ Router DTM System Interfaces
Stop any programs or processes that
access AMS Device Manager Server
1
Stop AMS Asset Portal Data
Collection or AMS Suite APM, if
running
Stop AMS Device Manager Server in
system tray if running
Install Server Plus Station software
(page 51)
Get new license codes, if required
(page 57)
Reapply the DeltaV System
Interface, if applicable (page 11)
Install required SNAP-ON
applications (
page 58)
2
Install AMS Suite Calibration
Connector application, if applicable
Install new T+H TACC components,
if applicable (
page 101)
3
Configure HART Over PROFIBUS
System Interfaces, if applicable
(page 101)
Install latest version of Web
Services, if required (page 109)
Add all Windows Users (local or
domain) to the AMSDeviceManager
Windows group
If you plan to continue using AMS
Asset Portal, restart Data Collection,
but if you have purchased AMS Suite
APM, contact PlantWeb Services for
assistance.
Check in all calibration routes
Back up existing database (page 16)
Consolidate existing databases, if
necessary (page 48)
Uninstall SNAP-ON applications
2
Uninstall AMS Suite Calibration
Connector application, if installed
Uninstall T+H TACC components, if
installed (refer to TACC guides
downloaded from T+H)
Remove any configured HART Over
PROFIBUS and HART Over PROFIBUS
/ Router DTM System Interfaces
Stop any programs or processes that
access AMS Device Manager Server
1
Stop AMS Device Manager Server in
system tray if running
Uninstall previous AMS Device
Manager software (page 18)
Install Client SC Station software
(page 54)
Install required SNAP-ON
applications (
page 58)
2
Configure required communication
interfaces (page 73)
Install new T+H TACC components,
if applicable (
page 101)
3
Configure HART Over PROFIBUS
System Interfaces, if applicable
(
page 101)
Add all Windows Users (local or
domain) to the AMSDeviceManager
Windows group