Specification Sheet
Table Of Contents
S1KSeriesInstructionManual•9
5.0 Operating Instructions
Theoutputoutletswillprovideprotectionfromsurgesandpowerfailures.Plug
yourcomputer,monitor,andother“datacritical”devicesintotheseoutlets.
Thesurgeprotectedoutletcanofferprotectionagainstsurgesandtransients
typicallycausedbylightningordisruptiveloadsinthebuilding.Intheeventof
utilitypowerfailure,thisoutletwillnotprovidebackuppowertotheload.Utilize
thisoutletwithlesscriticaldevicessuchasprinters,scanners,faxmachines,or
externalspeakers.
WiththeUPSpluggedin,pressandholdtheOn/Off/Testbuttonformorethan1
seconduntiltheLineNormalLEDislit.TheUPSwillperformself-testingeach
timeitisswitchedon.
PressandholdtheOn/Off/Testbuttonformorethan2secondsuntiltheLine
NormalorBackupLEDturnsoff.
Usetheself-testfunctiontoverifyboththeoperationoftheUPSandthecondi-
tionofthebattery.Innormalutilitypower,presstheOn/Off/Testbuttonforless
than1secondtoperformaself-testfunction.Duringtheself-test,theUPSrunsin
BackupMode.IftheUPSpassestheself-test,itreturnstoLineNormaloperation.
Ifaloadof<20wattsisconnectedtotheUPSandtheacpowerfailsorisdiscon-
nected,theUPSwillentertheGreenMode.Atthistime,thegreenLEDonthe
frontpanelwillashevery3to5seconds.Afterapproximately3minutes,theUPS
willshutdown,preventingadeepdischargeofthebattery.TheUPSwillreturnto
LineNormaloperationwhenacpowerreturns.
IftheUPSisintheBatteryBackupModeandtheloadisdecreasedto<20watts,
theUPSwillagainentertheGreenModeandwillshutdownwithin3minutes.
ApplicationofacpowerwillreturntheUPStoLineNormaloperation.
IftheGreenModeofoperationisnotdesired,itcanbedisabledbyholding
downtheOn/Off/Testbuttonuntiltwobeepsareheard.TheGreenModewillbe
disabledandwillremaininthismodeuntiltheUPSisturnedoff.