Instruction manual
Table Of Contents
- INSTRUCTION MANUAL HFID
- ESSENTIAL INSTRUCTIONS
- TABLE OF CONTENTS
- PREFACE
- DEFINITIONS
- SAFETY INSTRUCTIONS WIRING AND INSTALLATION OF THIS APPARATUS
- OPERATING AND MAINTAINING THIS APPARATUS
- GENERAL SAFETY NOTICE / RESIDUAL RISK
- AUTHORIZED PERSONNEL
- GASES AND GAS CONDITIONING (SAMPLE HANDLING)
- POWER SUPPLY
- ELECTROSTATIC DISCHARGE
- GENERAL PRECAUTIONS FOR HANDLING AND STORINGHIGH PRESSURE GAS CYLINDERS
- DOCUMENTATION
- COMPLIANCES
- GLOSSARY OF TERMS
- ANALYZER SYSTEM ARCHITECTURE
- SECTION 1: DESCRIPTION AND SPECIFICATIONS
- SECTION 2: INSTALLATION
- SECTION 3: OPERATION
- SECTION 4: MAINTENANCE AND SERVICE
- SECTION 5: TROUBLESHOOTING
- SECTION 6: REPLACEMENT PARTS
- RETURN OF MATERIAL
- LIST OF FIGURES AND TABLES
- SUPPLEMENT

NGA 2000 HFID
Instruction Manual
HAS64E-IM-HW
September 2008
2 - 6 Installation Emerson Process Management GmbH & Co.OHG
2-6 ELECTRICAL CONNECTIONS
NOTE
Electrical installation must be in compliance with
the requirements of NAMUR and DIN VDE and/or
any applicable national or local codes (like local
electricity supply enterprises (ESE)).
Refer to figure 2-3 and 2-4. Two electrical connections
are required on the Analyzer Module: POWER and NET-
WORK. On the Analyzer Module, two NETWORK con-
nectors are available, either of which is appropriate for:
1. Interconnection with the Backplane of the Plat-
form. (See Instruction Manual for the NGA 2000
Platform).
2. "Daisy-chaining" with other NGA 2000 compo-
nents.
Connect Analyzer Module POWER to a 24 VDC power
source with a voltage tolerance of ± 5 % and a minimum
power rating of 120 watts (either the Platform or external
power source).
Figure 2-4: Front Panel Controls, Indicators and Electrical Connections
Figure 2-3: Front Panel Electrical Connections
Network
Connection “1”
Network
Connection “2”
Power
Connection
Fuse
[T 6A 250 V (6x32 mm)]
HFID
POSSIBLE
EXPLOSION HAZARD
Hydro
g
en fuel
g
as is used in this instrument.
Do not remove fuel restrictor or operate at
greater than 50 psig. An explosion resulting
in severe
p
ersonal in
j
ur
y
or death could occur.
DANGER D′EXPLOSION
POSSIBLE
EXPLOSION
Do not operate flammable
sample without following
instructions in the Manual.
An explosion resulting in
severe personal injury or
death could occur.
Ne pas utiliser l
′
echantillo
n
inflammable avant d′avoir pris
connaissance des instructions
contenues dans le manuel. Le
non respect de ces instructions
peut entrainer une explosion
provoquant des blessure graves
ou mortelles.
FUEL
BURNER
AIR
250 V
POWER
OVEN
HEAT
FLAME
ON
PURGE
AIR
IGNITE
FUEL
OVERRIDE
24V
1 +
2 -
3 GND
LON
1
LON
2
WARNING
ATTENTION
Cet instrument contient du
g
az hydro
g
ene. Ne
retirez pas le limitateur d′de
combustible, et n′operez pas au plus de 50 psig
Ces conditions peuvent provoquer une explosion
entrainant des blessures graves mortelles.
WARNING
T 6A
!
!
!
!
ATTENTION
DANGER
Pressure Regulator
Burner Air
Front Panel LEDs
Pressure Regulator
Fuel