PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the UPS and its batteries. Please read this manual thoroughly before attempting to install or operate this UPS. This equipment can be installed and operated by individuals without previous training. 1. PowerSure Personal XT models are available for 230VAC supply voltages and loads.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 3 These units bear TUV GS mark, CE mark and comply with the following standards (limits value class B): EN 60950 (1998.8), EN 50091-1 (1994.4), EMI/RFI: EN550222 class B EMS: IEC 1000-4-2 (ESD) Level 3 IEC 1000-4-3 (RS) Level 3 IEC 1000-4-4 (EFT) Level 3 IEC 1000-4-5 (Lightning surge) Level 3 CAUTION: Although your UPS has been designed and manufactured to assure personal safety, improper use can result in electrical shock or fire.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 4 INTRODUCTION & SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure Personal XT Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. MAJOR COMPONENTS PowerSure ! Fault-LED RS232 “Lead-acid battery inside the enclosure” “Blei-Akkumulator innerhalb des Gehause” Output Receptacles INPUT FUSE:250V~,5A,T Status-LED MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.
“Lead-acid battery inside the enclosure” “Blei-Akkumulator innerhalb des Gehause” 110 mm 0° -40°C “Lead-acid battery inside the enclosure” “Blei-Akkumulator innerhalb des Gehause” ! Plug Units(s) into UPS 5 RS232 Remove from Box INPUT FUSE:250V~,5A,T MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.0A, 1Ø OUTPUT:230V~,50/60Hz, 700VA/420W, 3.1A MADE IN CHINA 9:51 RS232 6-06-2001 INPUT FUSE:250V~,5A,T MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.0A, 1Ø OUTPUT:230V~,50/60Hz, 700VA/420W, 3.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 6 NORMAL MODE OPERATION 1. Inspect the packaging carton and its contents for damage. Please inform the trasport agency immediately should you find signs of damage. Please keep the packaging in a safe for future use. 2. Plug the UPS into a wall outlet (see figure 1). Let the UPS charge the battery for at least 2 hours. You may use the UPS while the battery charges, but the UPS backup time will be reduced until the battery is fully charged.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 7 LED & ALARMS The front panel LEDs and audio beeps indicate the UPS status. Switch and LEDs Symbol Function On/off Turn the UPS system an and off. 1. Steady: Input power is acceptable; the UPS is in normal mode (online) Status-LED (green) 2. Blinking: Input power is out of tolerance; the UPS is battery mode. 3. Off: No input power or the battery is exhausted or the UPS is switched off. Fault-LED (red) ! 1.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 8 TROUBLESHOOTING If the UPS fails to operate properly, turn off the unit and repeat the steps in the installation section of this manual. If the problem persists, refer to the chart below: PROBLEM No indication, no beep even UPS is connected to mains power supply Green LED blinks, red LED off, 1 beep every 4 sec. Grenn LED blinks, red LED off, 1 beep every sec.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 9 COMMUNICATIONS You can use MultiLink™ Software to allow your UPS to communicate to your computer via your DB-9 communications port. A MultiLink Software CD is included in the box, or you can download it from our web site at www.liebert.com. The PowerSure™ Personal XT UPS contains a standard DB-9 receptacle located on the rear of the UPS unit.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 10 230V SPECIFICATIONS ELECTRICAL SPECIFICATION Model Number PSPXT450-230 PSPXT700-230 PSPXT1250-230 INPUT Voltage Frequency Amperage (maximum) Phase 2.6 A 230 VAC (197 - 262 VAC) 50 Hz ± 4Hz; 60 Hz ± 4Hz 4.0 A 12 φ 2W, Ground 7.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 11 LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer (collectively referred to as the "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TWO YEARS FROM THE DATE OF ORIGINAL PURCHASE from Liebert or the Liebert dealer or retailer.
PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 12 PowerSureTM Personal XT 450, 700, 1250 VA 230V Technical Support U.S.A. Outside the U.S.A. U.K. France Germany Italy Netherlands E-mail Web site Worldwide FAX tech support 1-800-222-5877 614-841-6755 +44 (0) 1793 553355 +33 (0) 1 43 60 01 77 +49 89 99 19 220 +39 02 98250 1 +31 (0) 475 503333 upstech@liebert.com http://www.liebert.