Data Sheet

4 004D-NS802 / 0413
EmersonNetworkPower.com/EnergySystems (North America)
EmersonNetworkPower.eu/EnergySystems (EMEA)
© Emerson Network Power Energy Systems North America 2013.
Business-Critical Continuity
, Emerson Network Power
, the Emerson Network Power logo, Emerson
®
and Consider it Solved are service marks and
trademarks of Emerson Electric Co. EnergyMaster
, eSure
, NetPerform
, NetReach
, NetSpan
, NetSure
and NetXtend
are trademarks of Emerson
Network Power Energy Systems North America. Any other product, brand, or company names or logos are the property of the respective owner.
While every precaution has been taken to ensure accuracy and
completeness herein, Emerson Electric Co. assumes no responsibility,
and disclaims all liability, for damages resulting from use of this
information or for any errors or omissions. Specifications subject to
change without notice.
NetSure
802 Series
OverviewTechnical Specifications
System Features
Nominal System Voltage 408-528V AC (480 nominal) or 176-264V AC (208 nominal)
Monitoring MCA controller with optional LMS1000 monitor
Output Capacity
Per System 16,000A
Power Bay (POB) 2000A (nominal), 2200A (full current limit)
Combination Bay Power 2000A (nominal), 2200A (full current limit)
Distribution 2400A
Distribution Bay (DOB) 6000A
Physical Characteristics
Dimensions (H x W x D), Weight Power Bay with Rectifiers: 84" x 24" x 30", 995 lbs.
Combination Power and Distribution Bay
List 1 and List 11 93.5" x 24" x 30", 830 lbs.
List 2 and List 12 84" x 24" x 30", 830 lbs.
AC Distribution Bay (PDSC): 84" x 10" x 30", 190 lbs.
Distribution Bay (DOB): 84" x 30" x 30", 850 lbs.
Environmental
Operating Temperature 0°C to +40°C (+32°F to +104°F)
Storage Temperature -40°C to +85°C (-40°F to +149°F)
Safety Compliance UL Listed (UL1801), CSA 22.2 (No. 225), c UL, NEBS Level 3
Ordering Information
Part Number Description
Main Bay Sup Bay Power & Distribution Bays
58214000001 58214000011 Distributed Architecture, Combination Power and Distribution Bay.
Individual AC feeds for each rectifier located above the bay for easy access.
Has internal bus, does not require overhead Main Battery Term Bars (MBTB)
but may be used with them.
58214000002 58214000012 Distributed Architecture, Combination Power and Distribution Bay.
Bulk feed, requires a list 30, 31 or 32 PDSC. Has internal bus, does not require
overhead Main Battery Term Bars (MBTB) but may be used with them.
58214000003 58214000013 400A Ferro Retrofit Power Bay
Accommodates existing AC infrastructure for 400A Ferros (100A @208 or 50A
@480). Requires overhead MBTB.
58214000004 58214000014 Bulk Feed Power Bay for New Centralized Applications
Requires 2 AC feeds (250A @208 or 100A @480). Requires overhead MBTB.
58214000005 58214000015 200A Ferro Retrofit Power Bay
Accommodates existing AC infrastructure for 200A Ferros (60A @208 or 25A
@480). Requires overhead MBTB.
58214000016 Distribution Bay
Used for distribution when power bays are deployed or for additional distribution
when combination bays are used. Requires overhead MBTB.
Rectifiers
486534003 High efficiency 200 amp eSure
rectifier R4812000Le (208V AC)
486532603 High efficiency 200 amp eSure
rectifier R4812000e (480V AC)
486532602 200 amp rectifier R4811600 (480VAC)
1
PDSC (with individual AC breakers)
2
Distribution
3
TPL Fuse Holders
4
Bullet Breaker/Fuse Holder
5
GJ Breakers
6
LMS1000 Monitoring System
7
I/O Cards
8
eSure
Rectifiers
(486534003 or 486532603)
1 2
3 4
5
6 7
8