Table of Contents
Step 1. Select System Frame(s), Main Bay or Supplemental Bay ........2
Step 2. Optional - Select Distribution Frame .....................................2
Step 3. Select Input Voltage Source (AC Input Source) ......................2
Step 4. Select Rectifier Model ...........................................................3
Step 5. Optional - Select AC Service Cabinet (PDSC) .........................3
Step 6. Optional - Select Transient Voltage Surge Suppression .........3
Step 7. Select Controller Accessory Cards .........................................4
Step 8. Select LMS1000 Monitoring Options .....................................4
Step 8a. Select LMS1000 Card/Software Options ................................ 5
Step 9. Select DC Distribution Device Types......................................6
Step 9a. Choose TPL Style Fuses ..........................................................6
Step 9b. Choose GJ/218 Style Breakers ................................................7
Step 9c. Choose Bullet-Type Circuit Breakers and Adapter Kit.............8
Step 9d. Choose TLS/TPS Fuses with Bullet-Type Fuse Holders .......... 10
Step 10. Optional - Select Small Distribution for Distribution Bay .....11
Step 11. Optional - Select Internal Return Bar (as needed) ................ 12
Step 12. Optional - Select External Termination Bus Assembly .........13
Step 13. Optional - Select External Return Bar Option ......................14
Step 14. Order Accessories (as needed) .............................................15
Note: Click on the step above to jump to that page. To return to the
Table of Contents, click on the main title of any page.
Description
The modular NetSure
™
802 power system is made up of an assort-
ment of bays that can be configured to meet any large -48 Volt
power requirement from 1000 A to 16,000 A. The basic power unit
is a nominal 200 A rectifier capable of up to 220 amps each at cur-
rent limit. The system accommodates up to 10 rectifiers per bay,
and the bays can be configured for distributed or centralized appli-
cations. There are also bays configured to retrofit 200 amp and 400
amp ferro rectifiers with minimum AC infrastructure cost.
NetSure
™
802 Series
DC Power System
400 A Ferro Retrofit Power Bay200 A Ferro Retrofit Power BayNetSure
™
802 Power Bay Power Bay with Distribution Bay