Figure 2-47
Power/Distribution Bay External Top-Mount Vertical Busbar Assembly (P/N 554874)
Assembly Procedure Step 3
(1) Main Negative Busbar, P/N 554875
Note: Apply Electrical Anti-Oxidation Compound
to busbar mating services.
Note: Concave side of Belleville washer faces
busbar; convex side faces hex nut.
(8) 3/8” Flat Washer, P/N 214204100
(8) 3/8” Belleville Washer, P/N 214825000
(8) 3/8-16 Hex Nut, P/N 228567100 Hand-tighten only.
Rear Top
of Bay
Assembled
View
STEP 3
Install “Main Negative Busbar” onto Bay
Negative Busbar.
Mount 554876 to the 554875.
Hardware:
214204100 (4)
21
4825000 (4)
228567100 (4)