5) Order DC input cable lugs as required per Distribution Only Bay DC Input Cable Sizes and Lugs
Selection in the ACCESSORY DESCRIPTIONS section.
6) Order one (1) “Twenty-Four (24) Position Bullet-Nose Circuit Breaker/Fuse Panel” per Distribution Bay as
required per List C.
7) If a different length MCA Network cable is required, order per Replacement/Additional MCA Network
Cables. Refer to the Installation Instructions (Section 5876) for Network cabling requirements.
8) Side cover panels are factory installed on one side of the bay. In installations where a Distribution Only
Bay is placed by itself, order (2) P/N 528633 side cover panels for the other side.
List 30: Optional 480VAC Input Bolt-On PDSC (AC Input 'Power Distribution Service Cabinet')
Features
Provides an AC Input Service Cabinet pre-wired to the Rectifier mounting positions.
Provides a 30 ampere AC Input Circuit Breaker rated for 22kA interrupting capacity for each Rectifier
position. Circuit breakers are pad-lockable.
Provides terminations for one or two AC input branch circuits.
Ordering Notes
1) Order one (1) List 30, List 31, or List 32 as required for each List 2 or List 12 ordered.
2) Order a List 35 if additional surge suppression is required.
List 31: Optional 480VAC Input Bolt-On PDSC (AC Input 'Power Distribution Service Cabinet')
Features
Provides an AC Input Service Cabinet pre-wired to the Rectifier mounting positions.
Provides a 30 ampere AC Input Circuit Breaker rated for 65kA interrupting capacity for each Rectifier
position. Circuit breakers are pad-lockable.
Provides terminations for one or two AC input branch circuits.
Ordering Notes
1) Order one (1) List 30, List 31, or List 32 as required for each List 2 or List 12 ordered.
2) Order a List 35 if additional surge suppression is required.
List 32: Optional 208VAC Input Bolt-On PDSC (AC Input 'Power Distribution Service Cabinet')
Features
Provides an AC Input Service Cabinet pre-wired to the Rectifier mounting positions.
Provides a 60 ampere AC Input Circuit Breaker rated for 65kA interrupting capacity for each Rectifier
position. Circuit breakers are pad-lockable.
Provides terminations for one or two AC input branch circuits.
Ordering Notes
1) Order one (1) List 30, List 31, or List 32 as required for each List 2 or List 12 ordered.
2) Order a List 36 if additional surge suppression is required.
List 35: Surge Suppression for 480VAC Input PDSC
Features
Provides two (2) surge suppression assemblies for the PDSC. One wired to Rectifier AC input circuit
breakers CB1, CB3, CB5, CB7, and CB9. The other to CB2, CB4, CB6, CB8, and CB10.
100kA interrupting capacity.
Overcurrent fusing and thermal protection.