♦ Expandable either left or right, cable connected.
♦ Surge suppression optional.
Restrictions
Maximum of nine (9) Secondary Power Only Bays per power system.
Requires external main battery termination bars.
Ordering Notes
1) Specify List A (480VAC Input) or List B (208VAC Input).
2) If List A specified, order ten (10) P/N 256933200 30A circuit breakers.
3) If List B specified, order ten (10) P/N 256937200 60A circuit breakers.
4) Order Optional Surge Suppressors per List 37 or List 38.
5) Order Rectifiers as required per P/N 486532602 or P/N 486532603 (480VAC Input) or P/N 486534003
(208VAC Input).
6) Order additional MCA customer alarm relay circuit card(s) as required per List 70, and optional MCA I/O
circuit cards per List 71.
7) Order optional LMS Expansion CPU circuit card and LMS options as required per List 63, and
SAG586505000. Also order additional LMS Network cables as required per Replacement/Additional LMS
Network Cables.
8) Order bay grounding lugs as required per Power Only Bay Frame Grounding Wire Sizes and Lugs in the
ACCESSORY DESCRIPTIONS section.
9) Order DC output cable lugs as required per Power Only Bay DC Output Cable Sizes and Lugs in the
ACCESSORY DESCRIPTIONS section.
10) Order AC input lugs as required per Power Only Bay AC Input, Two (2) Rectifier Feeds Wire Sizes,
Branch Circuit Protection, and Lugs in the ACCESSORY DESCRIPTIONS section.
11) Order external top-mount battery input busbar assembly, busbar shield kit, external top-mount ground
(load return) busbar assembly, and/or load return lug extension busbar assembly as required per the
appropriate sections located under ACCESSORY DESCRIPTIONS.
12) If Secondary Bays are placed on both sides of the Primary Bay, a different length MCA Network cable is
required that connects a Secondary Bay on one side with a Secondary Bay on the other side. Order per
Replacement/Additional MCA Network Cables. Refer to the Installation Instructions (Section 5876) for
bay line-up and MCA Network cabling requirements.
13) Side cover panels are provided with Primary Bays. These cover panels are used with Secondary Bays
when bays are placed next to each other. In installations where a Secondary Bay is placed by itself,
order (1) of each of the following side cover panels per exposed side: P/N 514482 and P/N 514484.
List 15: Secondary Power Only Bay, Ten (10) AC Feeds (Common Equipment)
Features
♦ Provides common equipment for one (1) power only bay rated for up to 2200 amperes.
♦ Mounted in a 7’0”H x 24"W x 30"D box framework.
♦ Provides ten (10) Rectifier mounting positions.
♦ In ferro replacement applications, will accommodate ten (10) AC inputs sized for 200A ferro rectifiers
(208V, 60A or 480V, 25A).
♦ Provides the Router Assembly.
♦ Provides mounting for optional LMS Expansion CPU circuit card.
♦ Provides a seven-slot card cage for mounting MCA customer alarm relay circuit cards, MCA I/O circuit
cards, and/or optional LMS I/O circuit cards.
♦ MCA and LMS Network bay interconnect cables provided (Qty. 1 P/N 514643, Qty. 1 P/N 509900).
♦ Expandable either left or right, cable connected.