List 116: Optional Internal Ground/Return Bar, 8-Panel Bay (Full Bay Length)
Features
♦ Provides two full bay length internal ground/return bars (one per side).
♦ See Load Distribution Connections under Wiring Illustrations in ACCESSORY
DESCRIPTIONS for load termination specifications.
♦ Includes two (2) Input Lug Landing Plate Assemblies (one per side).
♦ Can be configured for top or bottom feed.
Restrictions
For use in List 105 and List 108 only.
Ordering Notes
1) Order as required.
2) Specify mounting location of included Input Lug Landing Plate Assemblies: top for top-feed
or bottom for bottom feed.
3) List 116 internal ground/return bars are rated for 1200 Amps. List 148 is available to
increase that capacity to 2400 Amps and provide additional cable landing points. Each bay
can accommodate (1) List 148. List 148 offers cable termination at the rear of the bay and
the option of a bonding strap. Mounting location (top or bottom) of List 148 will be opposite
that specified for the Input Lug Landing Plate Assemblies of List 116.
4) Order load lugs as required per Distribution Devices and Lug Selection in ACCESSORY
DESCRIPTIONS.
List 117: Optional Internal Ground/Return Bar, 8-Panel Bay (Panel Length)
Features
♦ Replaces a Distribution Panel on the left and right side with a panel length
internal ground/return bar.
♦ Consists of two (2) ground/return bar assemblies and two (2) blank cover
panels.
♦ For installation in top feed or bottom feed arrangements. When used in top
feed arrangements, ground bar assemblies are installed in top most left and
right Distribution Panel mounting positions (appropriate blank cover panels are
also installed in these positions). When used in bottom feed arrangements,
ground bar assemblies are installed in bottom most left and right Distribution
Panel mounting positions (appropriate blank cover panels are also installed in
these positions). When an additional List 117 is ordered, these additional
ground bar assemblies are installed in the adjacent Distribution Panel mounting
positions (appropriate blank cover panels are supplied and installed in these positions).
♦ See Load Distribution Connections under Wiring Illustrations in ACCESSORY DESCRIPTIONS for load
termination specifications.
♦ See List 139 for a paralleling kit when two (2) List 117 are ordered for the same bay.
Restrictions
For use in List 105 or List 108 only.
Ordering Notes
1) Order as required. Order two (2) List 117 for a fully configured bay. Also order one (1) List 139
Paralleling Kit if two (2) List 117 are ordered.
2) Specify top feed or bottom feed to instruct the factory to mount the Internal Ground/Return Bars at the top
or bottom of the bay.
3) Order load lugs as required per Distribution Devices and Lug Selection in ACCESSORY
DESCRIPTIONS.