Application Guide

System Application Guide SAG584000300
NetSure 4015 30kW 400V DC Power System Issue AB, April 5, 2013
Spec. No. 584000300 (Model 4015-X003)
Page 11 of 32
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
Home
Power and Control Sub-Rack
List 11: Power and Control Sub-Rack HRMG (High Resistance Midpoint Grounded) Systems
Features
Provides the power and control sub-rack.
Provides two (2) rectifier mounting positions. A rectifier mounting position blank cover panel, P/N
553319, is furnished for each empty rectifier mounting position in the system.
Provides one (1) Model M820N ACU+ system controller. Provides the ACU+ IB2 interface board.
Provides a ground fault detection circuit. Provides a “System Shutdown” circuit.
Restrictions
Must be mounted in customer provided IT rack, unless ordered with List R1 or R2.
Must be used in a high resistance midpoint grounded application (±200V DC).
Ordering Notes
1) Order one (1) power and control sub-rack per system.
2) Order up to two (2) rectifiers (P/N 1R40015000e) per power and control sub-rack.
3) If ordered with List R1 or R2, factory programs ACU+ Controller for ordered configuration. If ordered
separately for customer integration, customer needs to program ACU+ for final configuration.
List 12: Power and Control Sub-Rack NPG (Negative Pole Grounded) Systems
Features
Provides the power and control sub-rack.
Provides two (2) rectifier mounting positions. A rectifier mounting position blank cover panel, P/N
553319, is furnished for each empty rectifier mounting position in the system.
Provides one (1) Model M820N, ACU+ system controller. Provides the ACU+ IB2 interface board.
Provides a “System Shutdown” circuit.
Restrictions
Must be mounted in customer provided IT rack, unless ordered with List R1 or R2.
Must be used in a negative pole grounded system (+400V DC, -0V DC).
Ordering Notes
1) Order one (1) power and control sub-rack per system.
2) Order up to two (2) rectifiers (P/N 1R40015000e) per power and control sub-rack.
3) If ordered with List R1 or R2, factory programs ACU+ Controller for ordered configuration. If ordered
separately for customer integration, customer needs to program ACU+ for final configuration.