Installation Manual
Emerson Network Power
Buried Distribution Products
631-200-108
Version B, March 18, 2013
Outside Plant Equipment Proprietary Information Page 11 of 14
4. INSTALLING EQUIPMENT IN THE ENCLOSURE
4.1 Overview - The CoolPed enclosure can accommodate up to four customer-supplied
weather-hardened DSLAMs, two in the front and two in the back, and an optional Emerson AC
Power Kit (ACPOWKIT F1007112), and various accessories as required by your specific
application.
4.2 You Will Need - To install equipment in the enclosure, you will need to supply:
• a 216-type tool;
• DSLAM manufacturer mounting bracket.
4.3 Procedure - Perform the following steps to install equipment in the enclosure:
Step 1: If the doors are not already open, then use a 216-type tool to open the doors, and
secure them with the wind latches.
Step 2: Depending on the DSLAM used, mounting to the horizontal rails will require
adaptor brackets to be supplied by the DSLAM provider. If required, affix brackets
to DSLAM per manufacturer requirements or local practice prior to mounting.
Step 3: Relocate the lower DSLAM horizontal rail as needed depending on which DSLAM
module is used by loosening the
1
/
4
" bolt on each end. See Fig. 11 for horizontal rail
location required for the given DSLAM module used.
EQUIPMENT
CONFIGURATION
BAR MOUNTING
POSITION
CALIX E3 - 48
ADTRAN TA1124 (1ST GEN)
& TA1148 (2ND GEN)
ADTRAN TA1148A/V (3RD GENERATION)
& TA1148 (4TH GENERATION)
A
B
C
A
B
C
RELOCATE BAR AS NEEDED
see DETAIL A
DETAIL A
Fig. 11 : Lower DSLAM Horizontal Rail