Step 4: Place the enclosure over the cable loop that extends from the ground.
Step 5: Mark the approximate locations on the ground where the stakes would mount on the
inside of each side of the enclosure (as shown in Fig. 10), and lift the enclosure out
and away from the hole.
Step 6: Pound the mounting stakes into the ground, in the locations indicated by the marks
you have made, so that the stakes will protrude at least 4 inches (10 cm) above the
finished grade. Take special care to drive the stakes straight into the ground.
WARNING
When stake mounting the enclosure, be careful not to damage the cable when
driving the stakes into the ground.
Step 7: If local bonding and grounding practices require a ground rod, install it, and attach
a sufficient length of 6 AWG copper wire to the ground rod with a ground rod
clamp, per local practices.
Step 8: Place the enclosure over the cable loop that extends from the ground, and align the
mounting locations on the side of the enclosure with the mounting holes provided
on the mounting stakes.
Step 9: Secure all cables inside the enclosure. Then reattach the lower cover.
mounting
stakes
holes for attaching
mounting stake to
enclosure
Fig. 10 : Mounting Stakes