3.3.1 You Will Need - To mount the enclosure using stakes and stabilizers, you will need:
• equipment to dig a trench;
• a 216-type tool;
•a
9
/
16
" hex socket wrench and a
9
/
16
"hex open end type or box end wrench; and
• a rubber mallet or hammer.
3.3.2 Procedure - Perform the following steps to direct bury the enclosure:
Step 1: Unpack the enclosure and dispose of the packing materials properly.
Step 2: Dig a rectangular hole with approximately the following dimensions: Length: 50
inches; Width: 30 inches; Depth: 10 inches.
ALERT
There should be about 5 inches (13 cm) between the bottom of the doors and the
finished grade level.
Step 3: To mount the stabilizers (one per side), locate kit inside enclosure packaging. Using
four hex head
1
/
4
-14 screws per side. Attach the stabilizer to the lower cover as
shown in Fig. 9. Bottom fin of the stabilizers are to be positioned outwards from the
enclosure.
stabilizer
Fig. 9 : Mounting Stabilizers