Installation Manual

Emerson Network Power
Buried Distribution Products
631-200-108
Version B, March 18, 2013
Outside Plant Equipment Proprietary Information Page 7 of 14
CAUTION
When moving a CoolPed DSLAM Enclosure from its pallet to the installation location,
be careful to not let the enclosure bend or flex as damage to the enclosure could
result.
Step 3: Slide the enclosure around the cable loop that extends from the pad’s cable opening.
Step 4: Secure all cables inside the enclosure, and reattach the lower cover.
Step 5: Align the four front and rear pad mounting flanges, located on the inside of the
enclosure’s base, with the anchors in the pad.
Step 6: Use the
1
/
2
-13 mounting bolts and washers, included in the loose parts bag inside
the enclosure, to secure the enclosure at each of the four mounting holes.
3.3 Direct Buried Mounting - Stakes and Stabilizers
Note: Mounting on a pad (as described in Section 3.2) offers the greatest stability for the
enclosure. If you are direct burying the enclosure, exercise care and extra
attention when leveling the enclosure.
Note: To ease installation, the doors of the enclosure can be removed, as well as either
of the lower covers.
21.0
(533mm)
17.0
(432mm)
43.2
(1098mm)
15.0
(381mm)
Fig. 8 : Bottom View of the Enclosure