Business-Critical Continuity™, Emerson Network Power, and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. NetSure™, NetSpan™, NetReach™, NetXtend™, and NetPerform™ are trademarks of Emerson Network Power, Energy Systems, North America, Inc. All other trademarks are the property of their respective owners. The products covered by this instruction manual are manufactured and/or sold by Emerson Network Power, Energy Systems, North America, Inc.
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 TABLE OF CONTENTS 1. ABOUT THIS DOCUMENT 1 1.1 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Reason for Reissue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.3 Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
631-200-108 Version B, March 18, 2013 Emerson Network Power Buried Distribution Products This Page Left Intentionally Blank Page ii of ii Proprietary Information Outside Plant Equipment
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 NETREACHTM COOLPED 3.0 PASSIVE DSLAM ENCLOSURE DESCRIPTION AND INSTALLATION 1. ABOUT THIS DOCUMENT 1.1 Purpose This practice provides a description of the CoolPed 3.0 (CPED1844) DSLAM Enclosure as well as installation instructions. 1.2 Reason for Reissue Whenever this practice is reissued, the reason for reissue will be stated in this paragraph. 1.
31-200-108 Version B, March 18, 2013 Emerson Network Power Buried Distribution Products 2.2 Construction The CoolPed 3.0 (CPED1844) DSLAM enclosure is constructed with mill-galvanized steel and has a durable painted finish. It is a round cornered, rectangular design, ventilation in the doors and cap provide optimal ventilation for up to four weather hardened DSLAM's. To ease installation, the lower cover can be removed by loosening the hex head bolts inside the base and lifting the cover up. 2.
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 2.5 Physical Specifications The CoolPed 3.0 (CPED1844) DSLAM enclosure weighs 195 lbs. Its dimensions are shown in Fig. 3. 17.8 (453mm) 43.8 (1112mm) 34.0 (864mm) 10.0 (253mm) 48.0 (1219mm) Fig. 3 : Dimensions CoolPed 3.0 (CPED1844) DSLAM Enclosure 3. INSTALLING THE ENCLOSURE CAUTION Notify the proper personnel, and perform all local safety procedures before installing the enclosure. 3.1 Preparation 3.1.
631-200-108 Version B, March 18, 2013 Emerson Network Power Buried Distribution Products 3.1.2 Procedure - Perform the following steps to prepare for the installation of the enclosure: Step 1: Place the enclosure as shown on the construction work prints. The cable or cables are normally placed on the trench line. When offsetting cables from the cable trench, the engineer needs to specify each location for the DSLAM enclosures and needs to indicate on the construction drawings the amount of offset.
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 ALERT Do not leave an excessive length of cable above the ground. 90 inches minimum (2.3 m) 36 inches (91 cm) minimum ground line ground line Fig. 4 : Cable Looped Through Enclosure Fig. 5 : Cable Not Looped Through Enclosure 45.7 (1161mm) 43.8 (1113mm) 61.1 (1552mm) Fig. 6 : Recommended "Keep-Out" Area for CoolPed 3.
631-200-108 Version B, March 18, 2013 Emerson Network Power Buried Distribution Products 3.2 Mounting the Enclosure on a Pad Note: To ease installation, the doors of the enclosure can be removed, as well as either of the lower covers. 3.2.1 You Will Need - To mount the enclosure on a pad, you will need to supply: • • four 1/2-13 threaded anchors and a 3/4" hex socket wrench. 3.2.
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 21.0 (533mm) 15.0 (381mm) 17.0 (432mm) 43.2 (1098mm) Fig. 8 : Bottom View of the Enclosure CAUTION When moving a CoolPed DSLAM Enclosure from its pallet to the installation location, be careful to not let the enclosure bend or flex as damage to the enclosure could result. Step 3: Step 4: Step 5: Step 6: Slide the enclosure around the cable loop that extends from the pad’s cable opening.
631-200-108 Version B, March 18, 2013 Emerson Network Power Buried Distribution Products 3.3.1 You Will Need - To mount the enclosure using stakes and stabilizers, you will need: • • • • equipment to dig a trench; a 216-type tool; a 9/16" hex socket wrench and a 9/16"hex open end type or box end wrench; and a rubber mallet or hammer. 3.3.2 Procedure - Perform the following steps to direct bury the enclosure: Step 1: Step 2: Unpack the enclosure and dispose of the packing materials properly.
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 holes for attaching mounting stake to enclosure mounting stakes Fig. 10 : Mounting Stakes Step 4: Step 5: Step 6: Place the enclosure over the cable loop that extends from the ground. Mark the approximate locations on the ground where the stakes would mount on the inside of each side of the enclosure (as shown in Fig. 10), and lift the enclosure out and away from the hole.
631-200-108 Version B, March 18, 2013 Emerson Network Power Buried Distribution Products Step 10: Use the 3/8-inch mounting hardware from the loose parts kit to secure the stakes to the enclosure. The stakes are to be mounted on the inside of the enclosure. (See Fig. 10) Step 11: Backfill around the outside of the enclosure with soil. At final grade, the top 5 inches (13 cm) of the lower cover should be above ground, and the bottom 4 inches (10 cm) should be below ground.
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 4. INSTALLING EQUIPMENT IN THE ENCLOSURE 4.1 Overview - The CoolPed enclosure can accommodate up to four customer-supplied weather-hardened DSLAMs, two in the front and two in the back, and an optional Emerson AC Power Kit (ACPOWKIT F1007112), and various accessories as required by your specific application. 4.
631-200-108 Version B, March 18, 2013 Step 4: Emerson Network Power Buried Distribution Products Using the 1/4-14 hex head screws provided in the loose parts kit, attach the DSLAM to the top and bottom horizontal rails using two screws each top and bottom (4 per DSLAM mounted). See Fig. 12. DETAIL A see DETAIL A wind latch 1/4-14 hex head screws Fig.
Emerson Network Power Buried Distribution Products 631-200-108 Version B, March 18, 2013 NOTES Outside Plant Equipment Proprietary Information Page 13 of 14
631-200-108 Version B, March 18, 2013 Emerson Network Power Buried Distribution Products 5. REVISION RECORD Issue Change Number (ECO) A RWN216612 New B RRM218470 Updates on CoolPed 3.0 CPED1844 cabinet design.
NetPerform™ Optimization Services At Emerson Network Power, we understand the importance of reliable equipment – it’s critical to both your business and your bottom line. That is why we offer a wide array of services to meet all of your network infrastructure needs. Technical Support Email Phone DCpower.TAC@Emerson.com OSP.TAC@Emerson.com 1.800.800.5260 Answers technical product and system questions; determines status of warranties and contractual agreements for repair.
Emerson (NYSE: EMR), based in St. Louis, is a global leader in bringing technology and engineering together to provide innovative solutions to customers through its network power, process management, industrial automation, climate technologies, and appliance and tools businesses. For more information, visit: Emerson.com.