Controlinc 1746-C (Version 5.21) Network Master Users Guide (2004-11-18)
5.1. Table Arrangement
Word
offset
into
table
Table [0]
----
System
Info Table
----
Read /
Write
Table [1]
----
Comm.
Error
Status
----
Read
Only
Table [2]
----
Interpreted
Valve
Status Bits
Reg [06]
----
Read
Only
Table [3]
----
Valve
Control
----
Discrete
Control
----
(O / C / S)
----
Read /
Write
Table [4]
----
Valve
Position
Feedback
----
0 – 100%
in 0.1%
increments
----
Read
Only
Table [5]
----
Valve
Control
----
Valve
Setpoint
----
0 - 4095
----
Read /
Write
Table
[6]
----
Analog
Input #1
----
Read
Only
Table
[7]
----
Analog
Input #2
----
Read
Only
Table [8]
----
Analog
Output #1
----
Read /
Write
Table [9]
----
Totalizer
#1
----
Read /
Write
Table [10]
----
Totalizer
#2
----
Read /
Write
Table [11]
----
Valve
Position
0 – 4095
reg [14]
----
Read
Only
Table [12]
----
Status Bits
for
Discrete
Digital
Input s
reg [05]
----
Read
Only
Table [13]
----
SSR
Config
----
Read /
Write
Table [14]
----
Additional
Register to
Poll from
All Valves
on Network
Read /
Write
Table [15]
----
Block of
Registers
polled from a
particular
valve.
Read /
Write
0
Table #
0x00
Table #
0x01
Table #
0x02
Table #
0x03
Table #
0x04
Table #
0x05
Table #
0x06
Table #
0x07
Table #
0x08
Table #
0x09
Table #
0x0A
Table #
0x0B
Table #
0x0C
Table #
0x0D
Table #
0x0E
Table #
0x0F
1
R / W
Command
0 0 R / W 0 R / W 0 0 R / W R / W R / W 0 0 R / W R / W R / W
2
Reserved
(F/W ID
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
3 ESD ESD ESD ESD ESD ESD ESD ESD ESD ESD ESD ESD ESD ESD ESD ESD
4
# Valves
on
Network
Valve #1
Comm
Status
Valve #1
Status
Valve #1
AOCS
Valve #1
POS
0 – 100.0%
Valve #1
STPT
Valve #1
AIN-1
Valve #1
AIN-2
Valve #1
AOUT
Valve #1
TTL - 1
Valve #1
TTL - 2
Valve #1
POS
0 – 4095
Valve #1
Status
Valve #1
SSR
Valve #1
Add Reg
Value
Valve #
5
Scan
Period
Size
Valve #2
Comm
Status
Valve #2
Status
Valve #2
AOCS
Valve #2
POS
0 – 100.0%
Valve #2
STPT
Valve #2
AIN-1
Valve #2
AIN-2
Valve #2
AOUT
Valve #2
TTL - 1
Valve #2
TTL - 2
Valve #2
POS
0 – 4095
Valve #2
Status
Valve #2
SSR
Valve #2
Add Reg
Value
Valve
(Actuator)
Type
6
Poll
Totalizers
Valve #3
Comm
Status
Valve #3
Status
Valve #3
AOCS
Valve #3
POS
0 – 100.0%
Valve #3
STPT
Valve #3
AIN-1
Valve #3
AIN-2
Valve #3
AOUT
Valve #3
TTL – 1
Valve #3
TTL - 2
Valve #3
POS
0 – 4095
Valve #3
Status
Valve #3
SSR
Valve #3
Add Reg
Value
Starting
Register
Number
7
Valve #4
Comm
Status
Valve #4
Status
Valve #4
AOCS
Valve #4
POS
0 – 100.0%
Valve #7
STPT
Valve #4
AIN-1
Valve #4
AIN-2
Valve #4
AOUT
Valve #4
TTL - 1
Valve #4
TTL - 2
Valve #4
POS
0 – 4095
Valve #4
Status
Valve #4
SSR
Valve #4
Add Reg
Value
Number of
Registers
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
63
See table [0]
Configuration &
Run-Time
Information
Valve #60
Comm
Status
Valve
#60
Status
Valve
#60
AOCS
Valve
#60
POS
0 – 100.0%
Valve
#60
STPT
Valve
#60
AIN-1
Valve
#60
AIN-2
Valve
#60
AOUT
Valve
#60
TTL - 1
Valve
#60
TTL - 2
Valve
#60
POS
0 – 4095
Valve
#60
Status
Valve
#60
SSR
Valve
#60
Add Reg
Value
See
Table [15]
Description
Word
offset into
table
Table [16]
----
Command to Monitor
&/or Control Discrete
Digital Outputs
Read / Write
Table [17]
----
Status of Discrete
Digital Outputs
Read / Write
Table [18]
----
System Type
Read Only
Table [19]
----
Firmware
Version ID
Read Only
Table [20]
----
Modbus Exception
Response
Indications
Read / Write
Table [21]
----
TEC2000 Inputs
[1000 – 1015]
Reg [1000]
Read / Write
Table [22]
----
TEC2000 Inputs
[1016 – 1031]
Reg [1001]
Read / Write
Table [23]
----
TEC2000 Inputs
[1032 – 1047]
Reg [1002]
Read / Write
Table [24]
----
TEC2000 Inputs
[1048 – 1063]
Reg [1003]
Read / Write
0
Table #
0x10
Table #
0x11
Table #
0x12
Table #
0x13
Table #
0x14
Table #
0x15
Table #
0x16
Table #
0x17
Table #
0x18
1 R / W 0 0 0 R / W R / W R / W R / W R / W
2
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
Reserved
(F/W ID)
3 ESD ESD ESD ESD ESD ESD ESD ESD ESD
4
Valve #1
Discrete Output Cmd
Valve #1
Discrete Out Status
Valve #1
System Type
Valve #1
Firmware ID
Valve #1
Exception Code
Valve #1
Inputs [1000-1015]
Valve #1
Inputs [1016-1031]
Valve #1
Inputs [1032-1047]
Valve #1
Inputs [1048-1063]
5
Valve #2
Discrete Output Cmd
Valve #2
Discrete Out Status
Valve #2
System Type
Valve #2
Firmware ID
Valve #2
Exception Code
Valve #2
Inputs [1000-1015]
Valve #2
Inputs [1016-1031]
Valve #2
Inputs [1032-1047]
Valve #2
Inputs [1048-1063]
6
Valve #3
Discrete Output Cmd
Valve #3
Discrete Out Status
Valve #3
System Type
Valve #3
Firmware ID
Valve #3
Exception Code
Valve #3
Inputs [1000-1015]
Valve #3
Inputs [1016-1031]
Valve #3
Inputs [1032-1047]
Valve #3
Inputs [1048-1063]
7
Valve #4
Discrete Output Cmd
Valve #4
Discrete Out Status
Valve #4
System Type
Valve #4
Firmware ID
Valve #4
Exception Code
Valve #4
Inputs [1000-1015]
Valve #4
Inputs [1016-1031]
Valve #4
Inputs [1032-1047]
Valve #4
Inputs [1048-1063]
~ ~ ~ ~ ~ ~ ~ ~ ~ ~
63
Valve #60
Discrete Output Cmd
Valve #60
Discrete Out Status
Valve #60
System Type
Valve #60
Firmware ID
Valve #60
Exception Code
Valve #60
Inputs [1000-1015]
Valve #60
Inputs [1016-1031]
Valve #60
Inputs [1032-1047]
Valve #60
Inputs [1048-1063]
Figure 5-1 Table Arrangement