User`s guide

Copyright © 2004 EIM COMPANY, INC. • 13840 PIKE ROAD • MISSOURI CITY, TX. 77489
Page 104
Controlinc 1746-C (Version 5.21) Network Master Users Guide (2004-11-18)
6.4.2. Specific Coils & Inputs Referenced by the Network Master
320A & 320B … (CPU reset in 320A version 1.30 & later)
Register BIT 15 BIT 14 BIT 13 BIT 12 BIT 11 BIT 10 BIT 9 BIT 8 BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
User Output
Relay 2
User Output
Relay 1
ESD /
Monitor
Relay
0
(coils)
RO 5 RO 4 RO 3
Enable
SSR Starter
2
(coils)
R/W 37
CPU has
Reset
4
(coils)
RW 78
Reserved
0
no-op
User Input
#2 Status
User Input
#1 Status
Aux Alarm
Input
Local ESD
Alarm
Phase
Monitor
Alarm
Thermal
Overload
Alarm
Power
Monitor
Alarm
TSC
Status
Indicator
TSO
Status
Indicator
SS in
Remote
Position
SS in Local
Position
Contactor
Aux Close
is Made
Contactor
Aux Open
is Made
LSC is
Tripped
LSO is
Tripped
5
(inputs)
RO 15
RO 14 RO 13 RO 12 RO 11 RO 10 RO 9 RO 8 RO 7 RO 6 RO 5 RO 4 RO 3 RO 2 RO 1 RO 0
Unit
Alarm
0
Actuator
Self-Test
Alarm
Local
ESD
Alarm
Phase
Monitor
Alarm
Thermal
Overload
Alarm
Power
Monitor
Alarm
Valve Stall
Alarm
TSC
Alarm
TSO
Alarm
SS in
Remote
Position
SS in Local
Position
Valve is
Closing
Valve is
Opening
LSC
Tripped
LSO
Tripped
6
(inputs)
RO 31
RO 30
RO 29 RO 28 RO 27 RO 26 RO 25 RO 24 RO 23 RO 22
RO 21 RO 20 RO 19 RO 18 RO 17 RO 16
TEC2000 …
Register BIT 15 BIT 14 BIT 13 BIT 12 BIT 11 BIT 10 BIT 9 BIT 8 BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
Alarm …
Unit
STOP
Command
Active
CLOSE
Command
Active
Open
Command
Active
SETUP
Mode
Selected
REMOTE
Mode
Selected
STOP
Mode
Selected
LOCAL Mode
Selected
TSC is
Tripped
TSO is
Tripped
Valve is
Closing
Valve is
Opening
LSB is
Tripped
LSA is
Tripped
LSC is
Tripped
LSO is
Tripped
1000
(inputs)
RO 1015
RO 1014 RO 1013 RO 1012 RO 1011 RO 1010 RO 1009 RO 1008 RO 1007 RO 1006 RO 1005 RO 1004 RO 1003 RO 1002 RO 1001 RO 1000
Alarm …
Low
Battery
Alarm …
Valve
Stalled
Alarm …
Over Torque
Valve is
Moving
Alarm …
EFM
Alarm …
Config
Error
Alarm …
Actuator
Failed
Alarm …
Lost Analog
Signal
Alarm …
ANY
ESD
Alarm …
Hardwired
ESD
Alarm …
Close
Inhibit
Alarm …
Open
Inhibit
Alarm …
Motor
Overload
Alarm …
Lost
Phase
Alarm …
Lost
Ctl Voltage
Alarm …
Valve
Drift
1001
(inputs)
RO 1031 RO 1030 RO 1029
RO 1028
RO 1027 RO 1026 RO 1025 RO 1024 RO 1023 RO 1022 RO 1021 RO 1020 RO 1019 RO 1018 RO 1017 RO 1016
Limits are
Set
Indicator
APD
Status bit
EFM Status
(bit -2 of 2)
EFM Status
(bit-1 of 2)
ACM-Digital
Net Status
(bit-2 of 2)
ACM-Digital
Net Status
(bit-1 of 2)
ACM-Analog
Status
(bit-2 of 2)
ACM-Analog
Status
(bit-1 of 2)
AUX Close
Contact
Engaged
AUX Open
Contact
Engaged
Digital Input
#6 State
Digital Input
#5 State
Digital Input
#4 State
Digital Input
#3 State
Digital Input
#2 State
Digital Input
#1 State
1002
(inputs)
RO 1047 RO 1046 RO 1045 RO 1044 RO 1043 RO 1042 RO 1041 RO 1040 RO 1039 RO 1038 RO 1037 RO 1036 RO 1035 RO 1034 RO 1033 RO 1032
Reserved
NO-OP
Reserved
NO-OP
Reserved
NO-OP
Reserved
NO-OP
Reserved
NO-OP
Reserved
NO-OP
COM 2
Alarm
COM 1
Alarm
RDM-2
Status
(bit-2 of 2)
RDM-2
Status
(bit-1 of 2)
RDM-1
Status
(bit-2 of 2)
RDM-1
Status
(bit-1 of 2)
LDM Status
(bit-2 of 2)
LDM Status
(bit-1 of 2)
CCM Status
(bit-2 of 2)
CCM Status
(bit-2 of 2)
1003
(inputs)
RO 1036 RO 1062 RO 1061 RO 1060 RO 1059 RO 1058 RO 1057 RO 1056
RO 1055 RO 1054 RO 1053 RO 1052 RO 1051 RO 1050 RO 1049 RO 1048
RO5 CMD
&
RO5 Status
SO8 CMD
&
SO8 Status
SO7 CMD
&
SO7 Status
SO6 CMD
&
SO6 Status
RO12 CMD
&
Status
RO11 CMD
&
Status
RO10 CMD
&
Status
RO9 CMD
&
Status
RO4 CMD
&
Status
RO3 CMD
&
Status
RO2 CMD
&
Status
RO1 CMD
&
Status
1004
(coils)
R/W 1011 R/W 1010 R/W 1009 R/W 1008 R/W 1007 R/W 1006 R/W 1005 R/W 1004 R/W 1003 R/W 1002 R/W 1001 R/W 1000