Technical data
Hardware Preparation and Installation
MVME6100 Single Board Computer Installation and Use (6806800D58E)
19
Jumpers/switches are used to control those options that are not software configurable. These
jumper settings are described further on in this section. If you are resetting the board jumpers
from their default settings, it is important to verify that all settings are reset properly.
Figure 1-1 illustrates the placement of the jumpers, headers, connectors, switches, and various
other components on the MVME6100. There are several manually configurable headers on the
MVME6100 and their settings are shown in Table 1-2. Each header’s default setting is enclosed
in brackets. For pin assignments on the MVME6100, refer to Chapter 5, Pin Assignments.
Items in brackets are factory default settings.
Table 1-2 Jumper and Switch Settings
Jumper/S
witch Function Settings
J7 SCON Header [No jumper installed]
1-2
2-3
Auto-SCON
Always SCON
No SCON
J10,
J15—J18,
J25—J28
PMC/IPMC Selection Headers [Jumper installed]
1-2
[2-3]
PMC I/O
IPMC I/O for IPMC7xx
support (default)
J30 Front/Rear Ethernet and
Transition Module Options
Header
Refer to Front/Rear Ethernet and Transition Module
Options Header (J30) on page 23 for details.
S3 SROM Configuration Switch,
sets board Geographical
Address
Refer to SROM Configuration Switch (S3) on page 24 for
details.
S4 Flash Boot Bank Select
Configuration Switch, sets
Write Protect A, Write Protect
B, Boot Bank Select, and Safe
Start
Refer to Flash Boot Bank Select Configuration Switch (S4)
on page 26 for details.