Data Sheet

Bulletin 71.1:MR95
20
Table 16. Steam Capacities
(1)
for 1/4 NPT and 1/2 through 1 in. / DN 15 through 25 Types MR95H and MR95HD Regulators with
Metal Diaphragm
RECOMMENDED
OUTLET/
DIFFERENTIAL
PRESSURE
RANGE,
psig/psi / bar
PRESSURE REGULATOR BODY SIZE, IN. / DN
Outlet/
Differential
Setting
Inlet
1/4 NPT 1/2 / 15 3/4 / 20 1 / 25
Droop Droop Droop Droop
10% 20% 10% 20% 10% 20% 10% 20%
psig bar psig bar lb/h kg/h lb/h kg/h lb/h kg/h lb/h kg/h lb/h kg/h lb/h kg/h lb/h kg/h lb/h kg/h
15 to 30 /
1.0 to 2.1
15 1.0
30
40
50
75
100
150
200
250
300
2.1
2.8
3.4
5.2
6.9
10.3
13.8
17.2
20.7
11
14
17
22
28
41
57
59
62
5.2
6.34
7.6
9.98
12.9
18.8
25.8
27
28.2
21
25
29
39
49
57
65
67
72
9.41
11.2
13
17.6
22.3
25.8
29.3
30.5
32.8
27
32
37
42
47
65
83
96
110
12.1
14.4
16.7
18.9
21.1
29.3
37.5
43.4
49.3
45
50
58
62
70
85
100
110
120
20.6
22.8
26.2
28.3
31.7
38.7
45.8
50.5
55.1
56
66
74
97
120
150
180
190
190
25.5
30.2
33.6
43.9
54.3
66.9
81
84.5
86.8
88
100
120
140
170
190
210
220
230
40
46.9
53.9
65.2
76.6
85.7
96.2
101
107
62
82
100
140
170
220
260
310
340
28
37.4
45.6
61.7
76.7
98.6
117
141
153
110
140
170
220
260
310
360
410
460
49.7
63.8
79
98.4
118
141
164
188
211
30 2.1
40
50
75
100
150
200
250
300
2.8
3.4
5.2
6.9
10.3
13.8
17.2
20.7
20
27
37
44
52
62
75
88
9.17
12.1
16.7
20
23.5
28.2
34
39.9
37
42
57
72
83
93
100
110
17
19.3
26.1
32.9
37.5
42.2
45.8
48.1
46
53
66
78
91
100
120
140
20.8
24.3
30
35.6
41.1
46.9
56.3
65.7
81
91
100
110
130
150
170
180
36.6
41.2
46.6
52.1
59.9
68
75.1
82.1
94
110
140
180
170
170
170
170
42.9
49.9
64.9
79.9
77.9
75.2
75.1
75.1
160
190
220
260
260
260
280
280
73.3
86.2
102
118
118
117
129
129
110
150
200
250
310
390
390
390
49
68.2
91.4
114
142
176
176
176
220
270
340
420
490
540
540
540
97.7
121
156
190
224
247
247
246
25 to 75 /
1.7 to 5.2
50 3.4
60
75
100
150
200
250
300
4.1
5.2
6.9
10.3
13.8
17.2
20.7
27
37
47
65
83
98
110
12.3
17
21.6
29.5
37.5
44.6
51.6
54
66
84
110
130
140
140
24.4
30.2
38.2
48.2
58.7
62.2
65.7
68
83
100
130
150
170
180
30.7
37.7
45.7
57
68.3
76.3
83.3
120
140
160
190
220
230
240
55
63
74.4
86.4
99.9
104
109
160
170
220
250
290
310
310
72.5
79.2
97.8
113
130
141
141
260
290
340
390
440
440
470
116
134
156
178
201
200
211
150
230
270
370
470
470
440
67.6
104
121
167
213
212
200
320
370
480
580
680
720
750
147
170
217
262
307
329
341
75 5.2
100
125
150
200
250
300
6.9
8.6
10.3
13.8
17.2
20.7
64
80
92
120
140
150
29.2
36.2
41.9
54.3
62.2
69.2
99
120
140
190
200
210
45
56.4
65.5
84.8
89.2
95
81
110
140
190
220
240
36.6
49.6
62.5
86.8
98
109
180
200
230
290
310
340
81.5
92.8
103
130
141
153
270
320
340
420
420
440
122
146
157
191
190
201
460
480
530
630
650
670
207
218
240
286
296
307
320
400
480
600
630
650
147
182
217
275
285
295
510
640
740
970
990
1000
231
290
336
441
450
472
70 to 150 /
4.8 to 10.3
100 6.9
125
150
175
200
250
300
8.6
10.3
12.1
13.8
17.2
20.7
59
72
82
92
110
120
26.9
32.7
37.3
41.8
49.7
56.4
96
120
140
150
170
190
43.7
54.2
62.2
69
79
88
150
170
190
210
230
260
66.1
77.7
85.7
94.9
106
118
240
270
290
320
340
390
108
121
132
144
154
177
320
370
430
480
530
580
147
170
194
217
239
262
540
610
660
740
790
840
244
279
301
336
358
380
350
460
510
560
660
760
159
207
230
253
299
345
560
720
820
920
1000
1200
256
327
374
420
477
534
150 10.3
175
200
225
250
300
12.1
13.8
15.5
17.2
20.7
92
110
130
150
180
41.7
51.1
59.3
67.4
83.5
140
170
200
220
260
65.8
78.7
89
98.2
119
240
270
290
320
340
109
122
134
145
156
380
430
450
450
470
171
194
205
205
215
350
430
480
510
610
160
195
219
230
277
700
830
880
960
1100
318
377
400
434
480
490
670
750
830
980
221
305
341
376
445
810
960
1100
1200
1500
367
438
497
567
695
1. Capacities are based in lbs/h / kg/h of saturated steam.