Specifications
PREFACE
SPECIFICATIONS – Probe/Sample Handling Enclosure: GENERAL
Power: Universal Power Supply 85 – 125 VAC, 50 – 60 Hz, + 10%
750 Watts Maximum at Start Up. 500 Watts Nominal
Mounting: Customer Flange Mount (2 Hole Top) or Wall Mount for High Temp Option
Area Classification: General Purpose / NEMA 4X Fiberglass Enclosure
Compliance's: CSA (Pending)
Ambient Range Temperature: -30
0
to 50
0
Celsius
Relative Hum: 5 to 99%
Instrument Weight: 95 lbs Typical
Size: 24“ X 34“ X 12“ (H W D)
Stack Sample Moisture: Up to 25% max
Sample Cooler: Thermo Electric dual pass Chiller. Permeation Tube (-30 degrees C.
Dewpoint. Customer instrument air required @ 5 L/M, -40 degree C dewpoint
Max. Stack Temperature: Standard 400
0
F.
Optional: 600 F (available with elongated spool option)
High Temp: 1400 F (Off Stack Option)
Stack Pressure: Typical -5 to 15 inches H
2
O
Sample Flow Rate: 500 to 2500cc/min
Response Time: Maximum distance between Analysis Enclosure and Sample
Conditioning/Probe Enclosure is 300'. (Response time is 30 seconds/100' w/1/4"
tubing)..
Probe Length: 48" length 316 SS Probe with .5 micron sintered filter. Customer to cut
to length in field if necessary. Optional 5’ and 6’ probes.
Mounting Flange: Standard 4“ 150# Raised Face. Shipped Equipped with Gasket
Sample Pump: 316 SS diaphragm type
Instrument Air Requirements: Instrument grade air required. 15 SCFM @ 60 -100 PSIG (30
seconds 2 times per day) Pressure Regulation by Customer
CUSTOMER SERVICE, TECHNICAL ASSISTANCE AND FIELD SERVICE
For order administration, replacement parts, application assistance, on-site or factory
repair, service or maintenance contract information, contact:
Rosemount Analytical Inc.
Process Analytical Division
Customer Service Center
1-800-433-6076
RETURNING PARTS TO THE FACTORY
Before returning parts, contact the Customer Service Center and request a Returned
Materials Authorization (RMA) number. Please have the following information when you
Rosemount Analytical µCEM Continuous Analyzer Transmitter 1