Application Guide
SAG586505000 System Application Guide
SAG586505500 Spec. No. 586505000 (Model LMS1000)
Issue AZ, April 7, 2014 Spec. No. 586505500 (Model LMS1000)
Page 34 of 62
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
• Set VPS/NPS Number of 25A, 50A, 100A, and 200A PCU Mounting Positions
Available in the System (also custom PCU sizes can be set)
• Reset VPS/NPS Inventory to Reflect Current System Configuration
• Set VPS/NPS System Float Voltage Setting
• Set VPS/NPS System Test/Equalize Voltage Setting
• Set VPS/NPS System High Voltage Shutdown Setting
• Set VPS/NPS System Current Limit Setting
• Set VPS/NPS Low Voltage Disconnect "Disconnect" Settings for all Installed LVDs
• Set VPS/NPS Low Voltage Disconnect "Reconnect" Setting
• Manually Reconnect a Specified LVD.
• Set VPS/NPS PCU Fan Speed (fast, slow)
• Set VPS/NPS PCU Load Share Alarm (on, off)
• Set VPS/NPS PCU State (on, off)
• Set VPS/NPS Digital Battery Charge Temperature Compensation Source (Highest,
Averaged, Probe #1)
• Set VPS/NPS Battery Overcurrent Alarm Setting
• Set VPS/NPS Digital Battery Charge Temperature Compensation (Slope, Min. Voltage,
Max. Voltage)
• Set VPS/NPS Battery Current Limit
• Set VPS/NPS Test/Eq Timeout
• Set VPS/NPS Individual PCU Custom Text Messages
• Set VPS/NPS Custom Text Message for MCA
• Set VPS/NPS Interface (on, off)
Available to LMS1000 Users with Access to Level 6 Commands via the
DOWNLOAD NETSURE , DOWNLOAD TFTP NETSURE , UPLOAD NETSURE ,
and UPLOAD TFTP NETSURE Commands, respectively
• Download the Configuration of the VPS/NPS to an ASCII File
• Upload a Previously Downloaded Configuration to the VPS/NPS
Each task supported by the MCA Interface is listed below for NPS Power Systems Spec.
Nos. 582140000, 582140001, and 582126100.
Available to LMS1000 Users with Access to Level 2
Commands via the PRCONFIG NPS Commands
• View NPS System Float Voltage Setting
• View NPS System Test/Equalize Voltage Setting
• View NPS System High Voltage Shutdown Setting
• View NPS System Current Limit Setting
• View NPS System High Voltage Alarm #1 Setting
• View NPS System High Voltage Alarm #2 Setting
• View NPS System Battery On Discharge Alarm Setting
• View NPS System Voltage is Very Low Alarm Setting
• View NPS System Total Load Current Alarm Setting
• View NPS System Group A Load Current Alarm Setting
• View NPS System Group B Load Current Alarm Setting