List 87: Power Metering Software Option
Features
♦ Refer to the "Specifications" section of this document for further information.
Restrictions
This option must be factory installed, or field installed by Emerson Network Power only. This option can be
field installed remotely via dial-up phone lines if your LMS1000 is equipped with a modem or via Ethernet if
connected to a TCP/IP network.
Ordering Notes
1) Order List 87 if Power Metering is required.
2) Order a List 20 analog circuit card. This analog circuit card provides 4 analog inputs. One will be
connected to system voltage. This leaves three for measuring customer loads. Order one additional
analog circuit card per four additional customer loads to be monitored. Note that there is also an 8-input
analog circuit card (List 22) available which monitors up to eight 50 mv shunts.
3) Also order one (1) in-line fuse kit to protect the analog leads connected to system voltage. Specify List
BE (3/8” ring lug), List BF (5/16” ring lug), or P/N 535135 (1/4” ring lug, 3/8” ring lug, or butt splice).
4) And order a current limit resistor kit for each customer load to be monitored for power consumption.
Specify List BA (3/8” ring lug), List BB (splice), or List BC (ring lug for #10 stud)
List 88: Local Port Redirection to OEM 1 Port Option
Features
♦ Local communications access is provided via the rear OEM 1 port instead of the front panel port.
Restrictions
The local port is redirected to the LMS1000 OEM1 Port. CANNOT be used if List 79, List 85, or List 86
ordered.
Not for use in Spec. Nos. 582140000, 582140001, and 582126100 Power Systems.
Ordering Notes
1) Order List 88 if the local port is required to be on the rear of the cabinet instead of on the front.
List 90: TL1 (over Ethernet) Software Option
Features
♦ With the TL1 (over Ethernet) software option, LMS1000 supports TL1 interface in a TCP/IP network. An
Ethernet port is provided for this network connection.
♦ Refer to the "Specifications" section of this document for further information.
Restrictions
CANNOT be used if List 86 is ordered.
Ordering Notes
1) Order List 90 if TL1 (over Ethernet) is required (see also List 86 for another TL1 option).
List 92: MCA Interface Cable, Customer Specified Length
Features
♦ A category 5, four twisted pair conductor, 24 AWG solid copper cable.
♦ Cable connects between the MCA of a Vortex Power System (VPS) or N
ETSURE Power System (NPS)
and the 586505000/586505500 Main Cabinet.
♦ Customer specified length cable.
♦ See also List 94.