Application Guide
System Application Guide SAG586505000
Spec. No. 586505000 (Model LMS1000) SAG586505500
Spec. No. 586505500 (Model LMS1000) Issue AZ, April 7, 2014
Page 17 of 62
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
Ordering Notes
1) Order List 79 if a Gateway Port is required.
2) If you are connecting the Gateway Port to a DGU, also order null modem cable P/N 545562 (5’) or
548010 (50’). This cable connects between the DGU and the LMS1000.
3) In Power Systems with an integrated controller shelf [NetSure 702, NetSure 801, NetSure 802],
connecting the Gateway Port to a DGU requires a straight through cable P/N 548009 be ordered. This
cable connects between the DGU COM1 card, Port A, and the LMS RS-232 port located on the front of
the LMS card assembly.
List 80: Door Access Controller (DAC) Interface
Features
♦ Configure and monitor the Door Access Controller via LMS1000.
♦ Refer to the "Specifications" section of this document for further information.
Restrictions
Interfaces to a Desarrollos Digitales Door Access Controller Model MKC-1 only.
The DAC Port is provided via the OEM3 (VPS/NPS) Port. If used with a VPS/NPS, customer must provide a
"Y" cable to allow both the Door Access Controller and VPS/NPS to be connected to the LMS1000 OEM3
Port.
Recommended to use a Desarrollos Digitales Isolation Board (Model DTP-1-485 / 96-DC24-T, E) between the
DAC and LMS1000.
Not for use in Spec. Nos. 582140000, 582140001, and 582126100 Power Systems.
Ordering Notes
1) Order List 80 as required.
List 82: PCU/Rectifier Sequencing Software Option
Features
♦ Provides PCU/Rectifier Sequential Start.
♦ Refer to the "Specifications" section of this document for further information.
Restrictions
Besides the sequencing software option, LMS1000 requires dedicated binary (VPS/NPS and traditional
rectifiers) and relay (traditional rectifiers only) inputs/outputs to manage the power plant. See the Wiring
section of the Installation Instructions (Section 5879).
The LMS1000 Sequencing feature is not for use in 582140000, 582140001, and 582126100 Power Systems.
Ordering Notes
1) Order List 82 if PCU/Rectifier Sequencing is required.
2) Order a binary circuit card if spare inputs are not available for a Commercial AC Fail/Transfer Detection
input and a Standby On/Proper Operate Detection input. (Binary channel 9011 'All AC Off' may be used
as the Commercial AC Fail/Transfer Detection input in a VPS/NPS Power System).
3) Order analog, binary, and relay circuit cards as required when used with 'traditional rectifiers'.
List 83: Energy Management Software Option
Features
♦ Provides PCU/Rectifier Energy Management
♦ Refer to the "Specifications" section of this document for further information.