Application Guide

SAG586505000 System Application Guide
SAG586505500 Spec. No. 586505000 (Model LMS1000)
Issue AZ, April 7, 2014 Spec. No. 586505500 (Model LMS1000)
Page 16 of 62
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
586505000 List 63 provides a new 23" off-white front panel.
586505500 List 63 provides a new 23" gray front panel.
List 70: Modem Circuit Card
Features
Provides for remote communications up to 56K BPS.
An RJ-11 jack (for telephone line connection) is provided on the rear of the 586505000/586505500
cabinet. In a Spec. No. 582140000, 582140001, and 582126100 Power System; the RJ-11 jack located
on the circuit card is used.
Plugs onto the Main CPU circuit card.
Refer to the "Specifications" section of this document for further information.
Restrictions
For use in a 586505000/586505500 Main Cabinet or 582140000/582140001/582126100 Primary Bay only.
Required for remote terminal or pager alarm notification via the System Alarm Reporting and/or Individual
User Alarm Reporting mechanisms.
Ordering Notes
1) Order a List 70 modem circuit card if remote communications and/or alarm reporting over a telephone line
is required.
List 78: LMS Dual MCA Interface Software Option
Features
Allows the MCA in a Spec. No. 582140000, 582140001, or 582126100 NETSURE Power System (NPS) to
interface with the MCA in a Vortex Power System (VPS) via the LMS.
Refer to the "Specifications" section of this document for further information.
Restrictions
Can only be used in the integrated LMS of a Spec. Nos. 582140000, 582140001, and 582126100 systems.
Operation of Energy Management is disabled when the Dual MCA Interface option is installed.
Ordering Notes
1) Order List 78 if a 582140000, 582140001, or 582126100 system is to interface with an MCA in a Vortex
Power System (VPS) via the LMS.
List 79: Gateway Port Software Option
Features
Allows the LMS1000 to emulate a “dumb” RS-232 asynchronous terminal interface. When installed, user
input through either a local or remote LMS1000 port is directed to the customer equipment connected to
the LMS1000 Gateway port.
When connected to a Lorain SMART DGU, automatically extends some LMS commands to the DGU and
returns DGU responses to user port.
Refer to the "Specifications" section of this document for further information.
Restrictions
In the 586505000/586505500 system, the Gateway port is provided via the LMS1000 OEM1 port. CANNOT
be used if List 85, List 86, or List 88 ordered.
In the Spec. Nos. 582140000, 582140001, and 582126100 Power Systems; the Gateway port is provided via
the port located on the front of the LMS1000 CPU circuit card installed in the Primary Bay.
Refer to the "Specifications" section of this document for further restrictions.
Home