Application Guide
SAG586505000 System Application Guide
SAG586505500 Spec. No. 586505000 (Model LMS1000)
Issue AZ, April 7, 2014 Spec. No. 586505500 (Model LMS1000)
Page 14 of 62
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
There are two kits offered for the 19" cabinet. One kit is used with the earlier version cabinet, the
other for the later version cabinet.
586505000 List 1 cabinets manufactured on or before 3/21/03, use kit P/N 524354 (586505000 List 61).
586505000 List 1 cabinets manufactured after 3/21/03, use kit P/N 524353 (586505000 List 60).
The later version cabinet has been modified to allow the LMS1000 Display Interface circuit card to be plugged
into the 10
th
LMS1000 I/O circuit card mounting slot. To determine exactly which kit is compatible with your
19" cabinet, look at the LMS1000 I/O circuit card backplane connectors. If all backplane connectors are
uniform, you have the earlier version cabinet and must use kit P/N 524354 (586505000 List 61). If the 10
th
I/O
backplane connector is longer then the others, you have a later version cabinet that uses Kit P/N 524353
(586505000 List 60). See the following illustration.
Requires the right-most I/O circuit card mounting slot.
Requires LMS1000 firmware 5.0.0 or later.
Requires use of the LMS1000 OEM2 Port. CANNOT be used if List 84 ordered.
Not for use in 23" cabinets.
Not for use in Spec. Nos. 582140000, 582140001, and 582126100 Power Systems.
Ordering Notes
1) Order one (1) List 60 to provide a front panel display and keypad in a later version 586505000 19"
cabinets. This option is factory installed if ordered with the system. This option is also field installable.
List 61: LMS1000 Display Option (for use in earlier version 586505000 19" cabinets)
Features
♦ Provides a front panel display and keypad.
♦ Allows local access to the system without a terminal.
♦ You can view plant voltage and load current, view active alarms, perform channel scans, view the Events
Log and Alarm Log, view channel statistics, and view battery discharge history.
Restrictions
There are two kits offered for the 19" cabinet. One kit is used with the earlier version cabinet, the other for the
later version cabinet.
586505000 List 1 cabinets manufactured on or before 3/21/03, use kit P/N 524354 (586505000 List 61).
586505000 List 1 cabinets manufactured after 3/21/03, use kit P/N 524353 (586505000 List 60).
The later version cabinet has been modified to allow the LMS1000 Display Interface circuit card to be plugged
into the 10
th
LMS1000 I/O circuit card mounting slot. To determine exactly which kit is compatible with your
19" cabinet, look at the LMS1000 I/O circuit card backplane connectors. If all backplane connectors are
Front Door
Opened in
Illustration
Determines earlier version vs. later version 19" cabinet.
Earlier Version Cabinet: I/O slot #10 is the same as the other I/O slots.
USE KIT P/N 524354 (586505000 List 61)
Later Version Cabinet: I/O Slot #10 has a larger (30 pos.) connector.
USE KIT P/N 524353 (586505000 List 60)