Specifications
Liebert NXL, Liebert Series 610
System Control Cabinet - SCC
When paralleling two or more units, a system control
cabinet monitors the output of the UPS’s and assures that
all of the outputs are synchronized. The System Control
Cabinet also contains a static bypass switch which assists
in the maintenance of the system.
System Control Cabinets are integrated into
the switchgear of your choice.
Centralized monitoring controls allow
for greater visibility into the system.
Liebert SCC’s 610 contains a static bypass switch
with manually operated disconnects and two
motor operated system circuit breakers.
Standard and custom power distribution switchgear
systems are available for use in Tier 1 through Tier 4
UPS system configurations.
Each SCC includes:
Microprocessor-based monitoring with
backlit LCD display, controls.
Momentary-duty static switch.
Continuous duty static switch options
with custom switchgear.
Automatic system isolation and bypass breakers.
Automatic equalize charge timer.
Interface for a remote power off.
Liebert SiteScan
®
Web interface.
Alarm status contacts.
RS-232 port.
Visual/audible alarms.
Factory System and Witness Testing
Emerson Network Power has invested in a state of the
art test facility to provide unmatched UPS system testing
at our factory for our clients. This facility enables us
to test system performance, proper unit function,
and proper system interoperability with a completely
integrated UPS system to meet our customers’ strict
criteria for system performance.
Factory witness testing allows our customers to see how
their systems will work in the field. We can simulate almost
any real world event, with real-time viewing of relevant
data, and results provided at the conclusion of each test.
Liebert Adaptive Power WitnessTest Center Features
Seven test bays, each with up to five distinct
test stations.
Witness test viewing station overlooking test bays and
equipped with LCD panel displays of current test data.
Total power over 12 MW available via the facility utilities.
Higher capacities supported through a 1.75 MW 50/60
Hz engine generator as well as plug-ins for additional
generators, as needed.
Liebert System Test Capability
Up to 9 multi-module UPS systems with integral
switchgear can be tested simultaneously.
The test infrastructure is designed to support large
lineups of equipment including switchgear, static
transfer switches, and distribution equipment.
Test infrastructure is supported with dedicated
battery simulators and both resistive and inductive
load banks which can be connected to different test
systems throughout the infrastructure.
Test currents, voltages, waveforms, THD, and other
critical information parameters are monitored
throughout the test infrastructure with high
accuracy power quality meters.
Test data is available locally in the test bays,
in the witness test rooms,or remotely for any use.
31
Enterprise UPS
31