Specifications
27
Cutting-Edge Power Technology
Makes The Difference
Liebert NX UPS Systems Incorporate
A Number Of Other Exceptional
Features:
High overload rating handles 125% for 10
minutes, 150% for one minute and a 1000%
overload for 10 milliseconds.
Digital controls provide the fastest possible
power management to enhance reliability,
accuracy and efficiency.
Front access models available for installation
along a wall. Front and rear access models
available for installation in a row.
Compact footprint requires less floor space,
leaving you with more room for other equipment.
Load Bus Synchronization standard.
Soft Switching technology increases efficiency
by up to 2% and saves energy.
Integrated ground fault detection allows for
effective transformer-less design while saving
space and lowering the unit weight.
Parallel for redundancy or capacity.
Active input rectifier is generator
and utility friendly.
Web card monitoring standard.
One year warranty.
Softscale
™
technology, paralleling capabilities and Eco-mode
™
all
contribute to lower initial, incremental and operating costs.
Liebert NX 40-200 kVA UPS Systems
Softscale Technology
Liebert NX 40-200 kVA UPS systems have Softscale technology that
provides flexibility to increase UPS capacity by 20 or 40kVA without
changes in your infrastructure. Allows paralleling of unlike-sized
models for capacity or redundancy. Designed for optimized
performance with the same high efficiency at 40% utilization as
at 100% utilization.
Paralleling Capabilities
Liebert NX 40-200 kVA systems allow you to parallel UPS modules
for capacity and redundancy, eliminating the batteries as a single
point of failure because each UPS has its own isolated battery.
Liebert NX also features integrated dual bus synchronization as a
standard feature. This provides the capability to synchronize the
outputs of two independent UPS modules when they are configured
as a redundant system feeding independent distribution paths.
Eco-Mode High Efficiency Configuration
If selected, this operating mode switches the UPS to static bypass
during normal operation, increasing efficiency to up to 97% at full
load. When power problems are detected the UPS automatically
switches back to double conversion mode.
Liebert NX BDC
The optional Liebert NX BDC provides flexibility in input and
output voltage for a variety of applications. This cabinet is available
in capacities to cover the Liebert NX UPS range of 40-200kVA.
The monitoring panel matches the UPS unit. Power and control
cabling from this cabinet to the UPS is included, enhancing ease of
installation and availability. For ease of installation and maintenance,
the cabinet offers top or bottom cable entry and models are available
in front and rear access, or front access only configurations.
Liebert NX
BDC
Battery
Cabinet
UPS
Liebert NX 160-200 kVA
Enterprise UPS
27