Specifications
523
Parallel
Communication
Ports
Electronic equipment
may be installed at
the front of the rack,
with the Parallel POD
installed at the back
of the rack, increasing
usable space.
Input/Output
Power For
Paralleled UPS Units
Equipment
shown from
back of rack.
The Parallel POD
enables paralleling of two Liebert GXT2 10 kVA
UPS modules to double capacity to 20kVA. A third
unit may be added to configure the system for N+1
redundancy, raising system reliability.
High capacity, compact on-line UPS with flexible output voltage and power distribution.
Other Product Features Of Liebert
GXT2 6 & 10 kVA UPS Models Include:
Wider input voltage window enables the UPS
to support the critical load without having
to transfer to battery.
Patented output neutral bonding feature meets
UL 1778 standard by providing a method for
maintaining the UPS output neutral to ground
bond in all modes of operation.
Internal bypass assures continuity of power
to critical loads during system problems
or maintenance.
Automatic frequency detection matches line
input frequencies of either 60 or 50 Hz.
User-replaceable hot swappable internal batteries
provide five minutes of runtime at full load.
Additional battery cabinets available for extended
backup time.
Liebert IntelliSlot
®
communications port utilizes
Liebert IntelliSlot
®
Web Card to provide SNMP
and web-based management.
Liebert Power Monitoring Capabilities
The operation of the UPS can be monitored using:
Liebert MultiLink
®
Automated System Shutdown Software.
Liebert Nform Monitoring System.
Liebert SiteScan
®
Web Centralized Monitoring System.
Third-Party Monitoring Systems.
For more information, see pages 44 and 45.
User replaceable
hot swappable
internal batteries
Liebert GXT2 6 & 10 kVA UPS
systems provide true on-line
protection in the smallest cabinets
in their capacity range. The UPS
systems offer internal batteries,
unlimited extended external
batteries, and internal bypass
capability, resulting in continuous
uptime for the connected
equipment. This makes the
UPS an ideal fit in applications
where the power requirements
are demanding—but rack space
is limited.
Application versatility is achieved
through the use of a dual inverter
design capable of providing
simultaneous output voltages
of 240/120, 208/120, 230/115,
220/110, or 200/100 VAC. The
input is power factor corrected to
approximately .98, enabling the
UPS to power a wide variety of
equipment with different voltages.
For installation flexibility, you may
choose from several different wiring
configurations made possible by the
use of removable power
distribution boxes that simply plug
into the rear of the UPS. Options
include hardwired or receptacle
connections, as well as maintenance
bypass capabilities.
Liebert GXT2 On-Line UPS:
6 & 10 kVA, 1-phase
10kVA
Liebert GXT2
UPS
10kVA
Liebert GXT2
UPS
10kVA
Liebert GXT2
UPS
PD-20X
Parallel
POD
Rack-Mount UPS