Liebert® APS™ User Manual – 5-20kVA Modular UPS
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.0 PRODUCT INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4 Long Run Time (LRT) Battery Temperature Probe Terminals . . . . . . . . . . . . . . . . . . . . . . . 41 3.5 USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 3.6 Liebert MultiLink® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3.7 LCD Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Estimated Battery Run Times. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 7.2.1 7.3 Estimated Battery Run Times. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.3.1 7.4 Tables for UPS Model Number Where Digits 1-3 are AS4 or ASD . . . . . . . . . . . . . . . . . . . . . 85 Estimated Battery Run Times. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 37 Figure 38 Figure 39 Figure 40 Figure 41 Figure 42 Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 Figure 61 Figure 62 Figure 63 Figure 64 Figure 65 Figure 66 Figure 67 Figure 68 Figure 69 Figure 70 Figure 71 Figure 72 Figure 73 Figure 74 Figure 75 Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 Table 18 Table 19 Table 20 Table 21 Table 22 Table 23 Table 24 Table 25 Table 26 Table 27 Table 28 Table 29 Table 30 Table 31 Table 32 Table 33 Table 34 Table 35 Table 36 Table 37 Table 38 Table 39 Table 40 Table 41 Table 42 Table 43 Table 44 Table 45 Table 46 Table 47 Table 48 Table 49 Table 50 Table 51 Table 52 Table 53 Table 54 Maximum load capacity of the output winding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions. Read all safety, installation and operating instructions before operating the Liebert® APS™ modular UPS system. Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions. Individuals must fully understand this equipment to install and operate it. This product is designed for commercial/industrial use only.
Important Safety Instructions ELECTROMAGNETIC COMPATIBILITY—The Liebert APS complies with the limits of Category C2, pursuant to IEC/EN/AS 62040-2, and for a Class A digital device, pursuant to Part 15 of FCC rules. Operation is subject to the following conditions: • The output cables shall be no longer than 10m (32ft). • This device may not cause harmful interference. • This device must accept any interference received, including interference that may cause undesired operation.
Glossary of Symbols GLOSSARY OF SYMBOLS Risk of electrical shock ! Indicates caution followed by important instructions AC input AC output i - Requests the user to consult the manual + Indicates the unit contains a valve-regulated lead acid battery PbH2SO4 R Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage 3 Liebert® APS™
Product Introduction 1.0 PRODUCT INTRODUCTION Congratulations on your purchase of the Liebert APS Uninterruptible Power System (UPS). As with every other Liebert product, we stand behind our quality. If you have any questions concerning this UPS, please feel free to contact your local dealer or Liebert representative or call the appropriate Technical Support number listed on the back of this manual. To ensure proper installation and operation of this unit, please read this manual thoroughly.
Product Introduction Figure 1 16-bay transformer-free UPS Liebert IntelliSlot® Ports Manual Bypass Breaker (under cover) Input Breaker (under cover) User Interface Module Bays for Power, Charger or Battery Modules Bays for Battery Modules System Control Module (under cover) Power Input and Output Terminals Dry Contacts and REPO Connections System Enable Switch USB Port Output Breaker FRONT VIEW (Bezels Removed) Figure 2 External Battery Cabinet Connector POD Ports REAR VIEW 10-bay transformer
Product Introduction Figure 3 12-bay transformer-based UPS Liebert IntelliSlot® Ports System Control Module (under cover) User Interface Module System Enable Switch Dry Contacts and REPO Connections Bays for Power, Charger, or Battery Modules USB Port Bays for Battery Modules External Battery Cabinet Connectors Ports for PODs Manual Bypass Breaker Output Breaker Input Breaker Power Input and Output Terminals Fans FRONT VIEW (Bezels Removed) Liebert® APS™ REAR VIEW 6
Product Introduction Figure 4 16-bay transformer-based UPS System Control Module (under cover) User Interface Module Liebert IntelliSlot® Ports Dry Contacts and REPO Connections Bays for Power, Charger or Battery Modules System Enable Switch USB Port POD Ports Battery Module Bays Input Breaker Output Breaker Manual Bypass Breaker (under cover) External Battery Cabinet Connector Power Input and Output Terminals Fans REAR VIEW FRONT VIEW (Bezels Removed) 7 Liebert® APS™
Product Introduction 1.
Product Introduction 1.3 Operating Principle The operating principle of the Liebert APS UPS is shown in Figure 5.
Product Introduction 1.4 Operating Modes The Liebert APS UPS is a true online double-conversion system, having the following operating modes: • • • • Normal Mode Backup Mode Auto Restart Mode Bypass Mode Normal Mode The power module rectifiers derive power from a utility AC source and supply regulated DC power to the inverter. The module’s inverter regenerates precise AC power to supply the connected equipment.
Product Introduction 1.5 Major Components This section provides a general description of each component and its functions. Please review this section carefully, as it will give you a better understanding of how the UPS operates. 1.5.1 UPS Frame The UPS frames are shown in Figure 6.
Product Introduction 1.5.2 User Interface Module The user interface module is shown in Figure 7. Figure 7 User interface module The user interface module is the primary source of communication between the UPS and the user. The user interface module permits: • • • • Viewing the UPS status Configuring the system Reviewing the event log Silencing the audible alarm Refer to 4.0 - Operation and Display Panel for details on operating the user interface module. 1.5.
Product Introduction 1.5.4 Power Module The power module is shown in Figure 9. Figure 9 Liebert APS power module Fan Green Status LED Yellow Fault LED Locking Lever FRONT VIEW Each power module is an independent 5kVA unit, consisting of a power factor corrected rectifier, battery charger and inverter, with associated monitoring and control circuitry. The modules are connected in parallel for greater capacity and/or redundancy.
Product Introduction 1.5.6 Charger Module Figure 11 shows the charger module. Figure 11 Appearance of the charger module Green Status LED Yellow Fault LED In AC mains mode, the charger module charges the system battery modules or external battery cabinet. Each charger module is rated to deliver 10A charging current. The charger module has an independent control function and maintains real-time communication with the system and the battery modules to ensure stable charging and fault protection.
Installation 2.0 INSTALLATION This chapter describes UPS installation, including installation preparation, unloading the UPS, mechanical installation, installing modules and cable connection. 2.1 Unpacking Inspection Upon receiving the UPS, uncrate it and conduct the following checks: • Inspect the UPS appearance for shipping damage. Report any shipping damage to the carrier and send a copy to your Emerson Network Power® representative.
Installation 2.2 Unloading the UPS The unit frame is bolted to the shipping pallet to ensure safety during shipping. Emerson recommends keeping the unit bolted to the pallet and using a pallet jack to transport the unit to its installation location. NOTE This UPS is very heavy. At least two people should assist in unloading it from the pallet. To unload the UPS: 1. Move the UPS to its installation site and remove the package paper. 2.
Installation 2.3 Mechanical Installation Two installation modes are available for the Liebert APS UPS: tower installation and rack installation. 2.3.1 Tower Installation 1. Once the UPS is in the desired location, adjust the leveling feet to secure its position, as shown in Figure 16. a. Use an open end wrench to turn the lower nut to raise or lower the leveling foot. b. After the unit is level, tighten the upper nut against the frame to prevent the height from changing.
Installation 2.3.2 Rack Installation 1. Install the cage nuts on the corresponding positions in the rack, as shown in Figure 18. a. Install cage nuts in the two lower square holes of 1U space and in the two upper square holes of 2U space of all four rack posts. These cage nuts will secure the optional shelf that will support the weight of the Liebert APS. b. Install a cage nut in the middle square hole of 4U, 6U, 10U, 12U spaces, respectively, again in all four posts.
Installation Figure 20 Install the guide rails Detail C Mounting Slot Insert one end of the guide rail into the mounting slot on the tray Guide Rail C 4. Unscrew the 10 screws on the front of the two side panels of the UPS frame. 5. Use those screws to attach the brackets to each side of the UPS frame, as shown in Figure 21. Figure 21 Install the brackets Bracket Screw (8 places) D Detail D Bracket 6. Push the Liebert APS frame slowly into the enclosure from the front, as shown in Figure 22.
Installation Figure 22 Push the UPS frame into the rack Front of Rack Front of UPS Push the UPS frame into the rack. Guide Rails 7. Use eight panel screws to secure the UPS frame to the rack posts, as shown in Figure 23. NOTE It might be necessary to use the leveling feet to get the holes to align Figure 23 Fix the UPS frame Panel Screw (8 Places) Detail E E 8.
Installation Figure 24 Install the metal plate Square hole (2 places) Metal Plate Screw (4 places) Detail F F 10. The installation is complete, as shown in Figure 25.
Installation 2.4 Module Installation The Liebert APS ships from the factory configured (modules prepopulated) and tested as a system to the customer’s requirements. If any modules were removed to facilitate ease of installation, follow the steps below to re-insert them properly. 2.4.1 Installing Power Module, Battery Module and Charger Module 1. Lift module to appropriate bay, resting end of module on bay shelf.
Installation Figure 27 Lever and fastener Pull Out Press Downward Before Pressing the Lever Side View After Pressing the Lever Side View NOTE If the lever of the module cannot be pressed down smoothly, remove the module and reinstall it. 4. Replace the small plastic bezels. 2.4.2 Install System Control and System Monitor Modules 1. Remove the display bezel and the user interface (LCD) module on top of the frame, as shown in Figure 28.
Installation Figure 29 Insert the System Control and System Monitor module 10mm Insert module here 3. Use a #2 Phillips screwdriver to install the screws into the holes on each end. 4. Slide the lever toward the right, as shown in Figure 30. Figure 30 Lever and fastener on System Control and System Monitor Module Mounting Hole Mounting Hole Lever Press and Slide to the Right Pull Out Before Pressing Lever After Pressing Lever 5. Replace the LCD module and display bezel.
Installation 2.5 Cable Connection ! WARNING Risk of electric shock. Can cause injury or death. Disconnect local and remote power supplies before working within. Read this section thoroughly before attempting to install wiring to this unit. Ensure that all the UPS input sources are disconnected off before attempting to install wiring to this unit. This UPS cables should be connected by a properly trained and qualified electrician.
Installation To connect the cable: NOTE Input and output cables must be run in separate conduit before cable connection. For the user whose input power grid is L-L line voltage, the input N of the power input and output terminals will connect live wire, so the output N of the power input and output terminals is also live wire. 1. Remove the knockouts at the junction box (see Figure 31) and pull the cables through them, leaving some slack for installation.
Installation Figure 33 Connection in 3-phase input OUTPUT PE 2 INPUT 1 PE 4 200V/208V/220V/230V/240V Table 5 3 2 1 380V/400V/415V Key to Figures 32 and 33 UPS wiring Input Terminal Block Output Terminal Block System Voltage System Nominal Frequency 1 2 3 4 PE 1 2 PE 200 60 L1 * L1 * L1 * L2 GND L1 L2 GND 208 60 L1 * L1 * L1 * L2 GND L1 L2 GND 220 60 L1 * L1 * L1 * L2 GND L1 L2 GND 230 60 L1 * L1 * L1 * L2 GND L1 L2 GND 240 60 L1 * L1 * L1
Installation 2.5.2 Transformer-Based UPS Cable Connection NOTE After the output transformer is installed, if the startup is on bypass, the UPS has a six-cycle inrush current that is up to 20 times the rated output current. This must be taken into account when selecting the input overload protection device at the AC input supply distribution point.
Installation Configuring the Bypass Voltage The UPS bypass voltage is factory-set to 208V (the jumper copper bar has been installed). Should the user have a utility supply of 200V/220V/230V/240V, the bypass voltage jumper must be changed to ensure correct output voltages when in bypass mode. Configuring the bypass voltage jumper settings are shown in Figures 34 and 35. Refer to Table 9 for the proper setting according to the AC mains voltage configuration.
Installation Configuring the Neutral/Earth Jumper The UPS contains an isolation transformer that generates a neutral conductor for the connected load. The UPS is a separately derived source and contains a neutral/earth jumper. A factory-installed neutral/earth jumper copper bar may require removal to comply with local codes and regulations.
Installation Figure 38 Connection method 208V Tap 240V Tap 1 2 3 OUTPUT PE GEC 4 3 2 1 1-3: 240V; 2-3: 208V; 1-4: 120V; 3-4: 120V (When the output voltage is set to 240V through LCD ) INPUT 1 2 PE 200V/208V/ 220V/230V/240V Factorysupplied jumper Refer to Table 7 for configuring the output cable. For standard voltages, make the connections shown in Table 9.
Installation 2.5.3 Transformer-Free UPS—Dual Inverter Frames A junction box is factory-installed on all models of the Liebert APS to ease cable connection. Select the appropriate input cables according to Tables 11 and 12 based on the UPS rating and mains frequency. Emerson recommends sizing the overcurrent protection and wiring for the frame rating for easing upgrades to the UPS system.
Installation 4. Respectively secure the input/output cables through the cable bridges on the rear panel of the UPS (see Figure 40). Figure 40 Secure cables on cable bridges The connections for the single-phase input mode and the 3-phase input mode are shown in Figure 32 and Figure 33, respectively. The copper jumper busbar is essential for the single-phase input mode.
Installation 2.5.4 Connecting External Battery Cabinet Up to four external battery cabinets may be connected to the Liebert APS to provide longer battery run times. An external battery cabinet contains a standard battery cable and a communication cable, each 1meter (39in) long. They are used to connect UPS and the external battery cabinet. Optional cables of 3 and 5 meters can be provided if the battery cabinets must be located some distance from the UPS cabinet. To connect an external battery cabinet: 1.
Installation Figure 43 Connecting external battery cabinet (transformer-based UPS) Communication Cable Battery Cable Liebert APS Battery Cabinet After connecting the external battery cabinet, use the user interface to determine the number of external battery cabinets, as shown in Figure 44. Figure 44 Battery screen Liebert APS Batt temp (e C) Discharge count Discharge hour (H) Ext batt-cab count 2012-01-01 10:45:20 25.0 303 9.
Installation 2.5.5 Connecting Integrated Power Output Distribution (POD) The rear panel of the Liebert APS UPS provides the capability to add integrated distribution outlets (PODs) as an option to allow direct AC power connection of the supported equipment to the UPS. These PODs are intended to allow the user to install and even change distribution, if necessary as equipment changes, while the UPS is still providing power. Follow these steps to properly and safely add or change the optional PODs. 1.
Installation Commissioning/Startup with AC Power Available (Normal Mode Operation) ___ 1. Verify that the upstream mains AC breaker is closed. ___ 2. Turn On the UPS Enable switch on the rear of the unit (it is protected by a clear plastic cover). ___ 3. Close the UPS input breaker: it is on the front of transformer-free frame systems and on the rear of transformer-based frame systems. NOTE This will begin the initial system checks and enable power to begin charging the battery ___ 4.
Communication 3.0 COMMUNICATION The rear panel of the Liebert APS provides these communication ports: • • • • • 3.
Communication Liebert IntelliSlot® Dry Contact Card (IS-RELAY) Provides dry contact alarm information, including: On Battery, On Bypass, Low Battery, Summary Alarm, UPS Fault and On UPS signals for communication to a remote monitoring system or for use with Liebert MultiLink® software. This card also can accept input signals to shut down the UPS while it is in any mode of operation.
Communication Any Mode Shut Down Pins 5 and 6: Input dry contact, normally open. After the external dry contact is closed (shorted), the UPS output will be shut down during any mode of operation (mains, battery, bypass). Battery Mode Shut Down Pins 7 and 8: Input dry contact, normally open. After the external dry contact is closed (shorted), the UPS output will be shut down only during battery mode operation. NOTE The default for the Any Mode and Battery Mode Shutdown features is disabled.
Communication ! WARNING Risk of electrical shock. Can cause property damage, injury and death. Operating the REPO circuit will NOT trip the manual bypass breaker. If the REPO must shut off UPS output under all circumstances, the user must tie the REPO into the breaker feeding the UPS source. Otherwise, voltage may be present on the output connections if the unit is in manual bypass. NOTICE Risk of improper installation. Can cause unintended UPS shutdown and loss of power to the load.
Communication 3.6 Liebert MultiLink® Liebert MultiLink monitors the UPS continuously and can shut down configured computers in the event of an extended power failure. Liebert MultiLink can also be configured to shut down the UPS. Liebert’s MultiLink can also be configured for use without the USB cable when the Liebert IntelliSlot® UNITY-S or UNITY-DP SNMP Card is installed in the UPS. An optional Liebert MultiLink License Kit permits shutting down the UPS over a network.
Operation and Display Panel 4.0 OPERATION AND DISPLAY PANEL 4.1 Overview This chapter describes the functions and operation of the UPS display panel. The LCD is composed of an LED mimic power flow diagram, fault LED indicator and LCD screen to show detailed operational information and UPS alarm list using the navigation buttons.
Operation and Display Panel Audible Alarms Three different audible alarms may occur during the UPS operation; see Table 18 for a description of the audible alarms. Table 18 Audible alarm descriptions Alarm sound Meaning One beep per second When the UPS has an alarm, for example, AC fault (mains failure) One beep every 0.
Operation and Display Panel 4.2 LCD Screen 4.2.1 Startup Screen When the UPS starts up, it will conduct a self-test, and the LCD will display the startup screen, which lasts for 15 seconds as shown in Figure 53. Figure 53 Startup screen 4.2.2 Main Screen The main screen is divided into four parts: system information window, data window, menu window and keyboard window, as shown in Figure 54.
Operation and Display Panel Menu Window and Data Window The menu window shows the menu name and allows navigation to different menu items. Each menu item has a set of data that is displayed in the data window. Using the menu window, you can browse the relevant parameters of the UPS and can adjust/set some operational parameters. See Table 22 for the menu and data descriptions.
Operation and Display Panel Table 22 Item description of menu window and data window (continued) Menu Name Data Item Set Redundancy Mode Remote Comms Shutdown Bypass Setting Output Frequency Output Voltage Inverter Sync Range Remote Shutdown Delay Bypass Upper Limit Bypass Lower Limit Settings Data Description Disabled/ Enabled.
Operation and Display Panel Table 22 Item description of menu window and data window (continued) Menu Name Data Item Communication Address Air Filter Reminder Air Filter Type Settings (continued) IT System Compatibility UPS ID Company Name Contact Number Load factory defaults Low battery Warning Automatic Battery Test Interval Battery settings Auto Batt Test Start Day Auto Batt Test Start Time External Battery AH Load Factory Defaults Language Language Options Alarms Records Current Alarms Histo
Operation and Display Panel Table 22 Item description of menu window and data window (continued) Menu Name Data Item Battery Maintenance Test Stop Battery Test System Test Stop Testing Freshening Charge Stop Freshening Charge Data Description Battery maintenance test allows battery to discharge some voltage to obtain the battery activity. The loads must be within 0% ~ 90%, the battery capacity must be larger than 70%, and there is no battery fault and alarm in the system.
Operation and Display Panel 4.2.3 Default Screen/Screen Saver During the UPS operating process, if there are no active alarms, the LCD will go into a screen saver mode after 2 minutes of no user navigation activity. The default screen saver is shown in Figure 55. After a brief delay, the LCD backlight will also turn Off. Pressing any button will return to the original screen. Figure 55 Default screen/screen saver 4.
Operation and Display Panel 4.3.2 Battery Screen From the main screen, press the F3 button once and the battery screen will be displayed, as shown in Figure 57. Figure 57 Battery screens Liebert APS Batt Voltage (V) Batt Current (A) Runtime (Min.) Batt Capacity (%) Batt State Batt String Count 2014 -01-01 10:45:20 157 .0 0.03 407 100 Batt Full Charge 0 Battery ▲ Liebert APS Batt Temp ( ) Discharge Count Discharge Time (H) EBC Count ▲ 2014 -01-01 10:45:20 25.0 303 9.
Operation and Display Panel 4.3.4 Load Screen From the main screen, press the F4 button once and the load screen will be displayed, as shown in Figure 59. Figure 59 Load screen Liebert APS kVA kW Load Level (%) Crest factor 2014-01-01 10:45:20 20.00 18.00 100.0 3.00 Load ▲ ▲ The load screen displays output kVA (Sout/apparent power), output kW (Pout/active power), load level and crest factor. 4.3.
Operation and Display Panel 4.3.6 Redundancy Screen From the main screen, press the F4 button three times until the redundancy screen is displayed, as shown in Figure 61. Figure 61 Redundancy screen Liebert APS PM Installed PM 2014-01-01 10:45:20 5 Redundant Redundant State ▲ ▲ The redundant screen displays the number of installed power modules in the frame, and whether the system contains a redundant module or not.
Operation and Display Panel 4.3.7 Settings Screen From the main screen, press the F4 button four times until the settings screen is displayed. The settings screen is displayed in a total of nine screens as you scroll down, as shown in Figure 62.
Operation and Display Panel 4.5 Setting or Changing a Parameter Setting 1. Press the F4 button to navigate to the parameter to be set, and press the F5 button to enter the edit mode. 2. Press the F3 or F4 button to select the setting item or change the setting value, then press the F5 button to confirm the setting. Press the F2 button to exit the edit setting mode.
Operation and Display Panel 4.5.1 Battery Setting Screen From the main screen, press the F4 button five times until the battery settings screen is displayed, as shown in Figure 63.
Operation and Display Panel 4.5.3 Alarms Screen From the main screen, press the F4 button seven times until the alarms screen is displayed, as shown in Figure 65. Figure 65 Alarms screen The alarms screen displays any current alarms of the UPS, including the alarm name, alarm ID code and alarm date/time stamp. 4.5.4 Records Screen From the main screen, press the F4 button eight times until the records screen is displayed, as shown in Figure 66.
Operation and Display Panel 4.5.5 Module Replacement Screen From the main screen, press the F4 button nine times until the module replacement screen is displayed, as shown in Figure 67. Figure 67 Module replacement screen Liebert APS 2014-01-01 10:45:20 LCD Board Bypass Monitor Board Bypass Control Board Power Module Battery Module Charger Module Liebert APS 1. Remove larger plastic bezel 2. Lift up on the LCD module 3. Swap the LCD module 4.Install the new LCD module 5.
Operation and Display Panel Table 24 Information and actions required for the prompt window Prompt Window Explanation Turn On/Off: Turn On UPS Cancel When you press the ON/OFF-button while UPS is Off. Turn On/Off: Turn On INV Turn Off UPS When you press the ON/OFF-button while UPS is operating on bypass mode. Turn On/Off: Transfer to Bypass Cancel When you press the ON/OFF-button while UPS is operating on inverter mode and bypass is qualified.
Troubleshooting 5.0 TROUBLESHOOTING This chapter provides the basic troubleshooting guide and required actions for maintaining the Liebert APS system. 5.1 Active Alarms In the event of an alarm, the User Interface LCD will display the latest alarm message. A list of possible alarm messages are displayed in Table 25. If an alarm occurs and you are uncertain of the corrective action to take, contact your local Liebert Services representative.
Troubleshooting Table 25 Alarm message list (continued) Alarm Message Possible Cause Corrective Action The battery is reversely connected. Have a qualified electrician check the wiring rotation at the external battery cabinet. If this is not the problem, contact your local Liebert Services representative. No Battery Modules Are Ready The battery module is not ready, and the yellow fault LED flashes. Ensure that the battery module is fully inserted and locking levers are in the locked position.
Troubleshooting Table 25 Alarm message list (continued) Possible Cause Corrective Action Low Battery Warning The battery capacity has reached the user programmable set point. Check upstream feeder breaker or the UPS input breaker and reset if necessary.If this is not the problem, begin the orderly shutdown of all connected equipment as UPS shutdown is imminent. Battery Module Warning One or more battery modules is abnormal.
Troubleshooting Table 25 Alarm message list (continued) Possible Cause Alarm Message 5.2 Corrective Action Charger Module LOCK Lever in Remove Position The locking lever is not in the locked position. Check the locking lever to ensure it is fully inserted. If so, contact your local Liebert Services representative. Charger Module Fan Failure One or more of the charger module fans has failed. Check to see if the fan is blocked. If not, contact your local Liebert Services representative.
Troubleshooting 5.3 Module Replacement Follow the instructions below when replacing or adding a system control, system monitor, power, battery, or charger module. Contact your local Liebert representative if you need to purchase additional modules to expand your system or contact authorized your Liebert Services representative for replacement modules. 5.3.1 Removing Modules 1. Remove bezel cover to locate the faulty module. The yellow fault LED will be illuminated on the faulty module.
Troubleshooting Figure 71 Pull out a battery module, a power module or a charge module Step 3 Step 3 Step 3 ! WARNING Risk of heavy unit falling over. Can cause equipment damage, injury or death. Read all of the instructions before attempting to move the unit, lift it, remove packaging or prepare the unit for installation. The UPS presents a tipping hazard. Do not remove more than one module at a time. Failure to do so may cause unit to tip over and cause serious injury.
Troubleshooting 5.3.2 Replacing the User Interface Module 1. 2. 3. 4. 5. Remove the display bezel on top of the frame. Lift up the user interface module, and put it on top of the UPS frame. Disconnect the network cable from the user interface module. Connect the network cable to the new user interface module. Insert the new user interface module into the clips and replace the display bezel.
Maintenance 6.0 MAINTENANCE This chapter describes the routine maintenance for the Liebert APS UPS, including proper care, scheduled maintenance and procedures for cleaning fan filters. 6.1 Proper Care Proper maintenance of the UPS is imperative to optimal performance and life of the unit. Emerson recommends that a certified technician perform preventive and corrective maintenance.
Maintenance 6.3.2 Bezel Filter 1. Remove the bezel from the frame. 2. Remove the filter assembly from the bezel, as shown in Figure 74, and clean the filters as described above. 3. Restore the filter and small plastic bezel of the frame. Figure 74 Replace/clean the bezel filter 6.3.3 Bottom Fan Filter—Transformer-Based Frames Only 1. Remove the three lower bezels at the bottom of the frame. 2. Remove the screws and take out the filter, as shown in Figure 75, and clean the filters as described above. 3.
Specifications 7.0 SPECIFICATIONS Table 27 Liebert APS specifications 10 Bay Unit Size, Type Frame Rating, kVA/kW General & Environmental Conducted and Radiated EMC Levels Compliant Safety Standards 16 Bay 12 Bay No Transformer 15/13.5 16 Bay Transformer-based 20/18 15/13.5 20/18 10 Bay 16 Bay No Transformer Dual Inverter 15/13.5 20/18 IEC/EN/AS 62040-2 Cat 2, CISPR22 Class A, FCC Part 15 Class A IEC/EN/AS 62040-1:2008, UL 1778 4th Ed and CSA 22.2 No. 107.3 UL 1778 4th Ed and CSA 22.2 No.
Specifications Table 27 Liebert APS specifications (continued) 10 Bay Unit Size, Type Frame Rating, kVA/kW Battery Module Lead-Acid Batteries Per String, Pieces Battery Cells Per String, Pieces Battery Capacity, W Backup Time, Minutes, Full Load Maximum Charge Current (Full, Load) Nominal Voltage, VDC Recharge Time, Hr Output Data Output Voltage, VAC 16 Bay 12 Bay No Transformer 15/13.5 Transformer-based 20/18 15/13.
Specifications Table 29 Liebert APS external battery cabinet specifications Parameters AS7EBCNCC1BX000 General and Environmental Conducted and Radiated EMC Levels Safety Standards Immunity Standards Transportation IEC/EN/AS 62040-2—Class A, FCC Part 15 (Class A) IEC/EN/AS 62040-1:2008, UL 1778 4th Ed and CSA 22.2 No. 107.3 IEC/EN/AS 61000-4-2, 3, 4, 5, 6 ISTA-1E 17x28x38 (440x712x970) Dimensions, WxDxH Unit Weight, lb (kg) 147.7 (67) Shipping Weight, lb (kg) 209.
Liebert® APS™ 27 28 29 30 31 32 - - - - - - - - - - - - - - - - - - 90% 80% 70% 60% 50% 40% 72 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - 113 135 147 156 164 187 202 215 226 308 317 324 331 337 342 347 423 427 431 434 437 440 443 445 448 450 452 10 16 21 91 64 48 41 33 27 23 26 33 99 75 53 48 43 38 39 44 48 97 77 66 52 52 63 70 94 78 76 81 97 93 99 105 110 120 126 131 135 139 143 146 149 152 155 157 160 16
73 1 5 6 8 9 11 15 19 27 44 99 - - - - - - - - - - - - - - - - - - - - Load Level 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - 99 44 27 20 15 11 9 8 6 5 166 104 66 47 38 28 25 21 18 16 2 98 44 27 20 15 11 9 8 6 5 144 73 46 34 26 20 17 14 12 10 312 148 108 78 60 48 42 36 30 26 3 132 63 4
Liebert® APS™ 74 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 111 129 140 148 155 161 166 188 199 209 218 226 306 312 318 324 329 333 337 341 345 420 424 427 429 107 131 145 156 165 191 207 221 304 314 323 331 337 343 420 425 429 433 437 440 443 446 449 451 453 455 457 459 133 153 166 203 224 312 326 336 345 425 431 437 442 446 450 453 457 459 462 464 466 480 480 480 480 480 480 480 480 - - - - - - - - - 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - -
75 - - - - - - - - - - - - - - - - - - - 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - 99 44 27 19 15 11 9 8 6 5 2 3 99 44 27 20 15 11 9 8 6 5 166 104 66 47 38 28 25 21 18 16 4 144 73 46 34 26 20 17 14 12 10 312 148 108 78 60 48 42 36 30 26 5 166 105 67 47 38 28 25 21 18 16 345 185 142 110 90 71 53 48 44 39 6 213 133 91 64 48 41
Liebert® APS™ 76 5 - - - - - - - - - - - - - - - - - - - - 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - 78 39 25 18 14 11 9 7 6 2 Load Level 1 90 41 26 19 14 11 9 7 6 5 154 92 53 44 35 27 23 20 17 15 3 136 67 44 32 25 20 16 14 11 10 216 138 99 72 52 46 40 34 28 26 4 160 98 62 46 37 28 25 20 18 15 327 161 133 104 80 67 52 47 43 3
15 38 19 46 27 64 106 140 159 189 215 307 322 334 344 424 431 437 443 447 451 455 458 461 463 466 480 480 480 480 480 480 480 480 480 480 480 480 480 43 102 147 180 219 316 334 420 431 439 446 452 457 461 465 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 96 164 308 342 434 448 457 465 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 - - - - - - - - - - - - - - - - - - - - - - - - - - -
Liebert® APS™ 78 14 15 16 17 18 19 20 # Battery Strings 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 110 131 144 153 161 180 196 209 221 303 312 319 326 332 338 343 420 424 428 431 434 437 440 443 445 447 450 452 453 455 111 130 141 150 158 164 184 198 209 219 300 308 315 322 328 333 338 342 346 422 425 429 432 434 437 439 442 444 446 111 129 139 148 155 161 166 187 199 209 218 226 305 312 318 323 328 333 337 341 345 420 423 426 429 432 434 437 101 112 129 138 146 152 158 163 167
79 27 28 29 30 31 32 33 34 35 - - - - - - - - - - - - - - - - - - 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% - - 30% - - 40% 10% - 50% 20% - 60% - - 70% - - 80% 30% - 90% 40% - - 10% 100% 96 164 308 342 434 448 457 465 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 26 43 102 147 180 219 316 334 420 431 439 446 452 457 461 465 480 480 480 480 480 48
Liebert® APS™ 80 - - - - 11 - 14 - 18 - 25 - 38 90% 80% 70% 60% 50% 40% 30% 20% 11 12 13 14 15 16 17 18 19 20 # Battery Strings 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 111 129 139 148 155 161 166 187 199 209 218 226 305 312 318 323 328 333 337 341 345 420 423 426 429 432 434 101 112 129 138 146 152 158 163 167 190 200 209 217 225 303 309 315 320 325 329 333 337 341 344 347 422 425 103 113 129 137 145 151 156 161 165 183 193 202 210 218 224 302 308 313 318 32
81 - - - - - - - - - - - - 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% - - - - - - - - - - 83 41 26 19 14 11 105 133 149 161 186 207 223 309 320 330 338 345 423 428 433 438 441 445 448 451 454 456 459 461 463 464 466 480 480 480 98 62 46 37 28 23 20 17 15 95 72 53 47 42 37 31 94 75 64 51 48 97 79 70 61 99 82 74 91 97 103 108 112 123 128 133 137 140 144 147 150 153 156 158 160 163 101 107 112 123 129 134 138 142 146 149 152 155 158
Liebert® APS™ 82 - - - - - - - - - - - - - - - - 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 33 - 32 - 31 70% 30 80% 29 - 28 - 27 90% 26 100% 25 71 147 203 317 342 431 443 452 459 465 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 24 35 23 10% 22 20% 21 22 20 16 - - - - - - - - - - 75 38 25 18 14 11 9 7 6 5 79 50 41 125 142 155 165 193 211 226 310 320 329 337
83 - - - - - - - - - - - - - - - - - - - 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - 82 40 25 18 14 11 9 7 6 5 83 41 26 19 14 11 9 7 6 5 158 96 53 44 36 27 23 20 17 15 3 135 67 44 33 25 20 16 13 11 10 225 141 101 73 52 46 40 34 28 26 4 159 98 62 46 37 28 23 20 17 15 333 164 135 105 81 67 52 47 42 38 5 197 126 81 60 47 39 32 27
Liebert® APS™ 84 24 25 26 27 28 29 30 31 32 33 - - - - - - - - - - - 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 71 147 203 317 342 431 443 452 459 465 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 23 35 22 - 21 20% 20 - - - - - - - - - - - 22 75 38 25 18 14 11 9 7 6 5 79 50 41 32 107 126 138 147 155 161 167 190 203 213 222 303 310 317 323 328 333 338 342 346 422 425 428 431 434 436 125 142 155 16
85 - - - - - - - - - - - - - - - - - - - - - - - - 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 67 44 32 25 20 16 13 11 10 76 53 47 41 35 28 26 79 66 52 47 43 83 72 62 51 92 76 68 91 97 103 108 112 123 128 133 137 140 144 147 150 153 156 158 160 163 165 166 95 101 107 112 123 129 134 138 142 146 149 152 155 158 161 163 165 167 185 190 195 80 99 106 112 124 130 135 140 144 148
Liebert® APS™ 86 14 15 17 18 19 20 # Battery Strings 16 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 109 126 135 143 150 156 161 165 185 195 204 213 220 227 305 311 317 321 326 330 334 338 341 344 347 422 425 22 34 70 146 201 315 341 430 442 451 459 464 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 30% 20% 10% 100% 90% 80% 70% 60%
87 - - - - - - - - - - - - - - - - - - - - - - - - - 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 83 41 26 19 14 11 9 7 6 5 110 128 139 147 154 160 165 186 197 208 217 225 304 311 317 322 327 332 336 340 344 347 423 426 428 431 434 109 130 143 153 160 167 194
Liebert® APS™ 88 - - - - - - - - - - - - - - - - - - - - - - - - 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 75 38 25 18 14 11 92 107 126 137 147 155 161 166 190 202 213 222 302 310 317 323 328 333 338 342 346 421 425 428 431 434 436 439 441 124 142 155 165 193 211 226 310
24 25 26 27 28 29 30 31 32 - - - - - - - - - - - - - - - - - - - 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 79 111 139 155 166 199 218 305 318 328 337 345 423 429 434 439 443 446 450 453 455 458 460 462 464 466 480 480 480 480 109 143 161 195 220 311 326 337 347 427 434 440 445 449 453 457 460 462 465 467 480 480 480 480 480 480 480 480 480 480 89 76 47 35 26 21 17 14 11 10 94 65 48 41 33 27 23 21 92 72 5
Liebert® APS™ 90 - - - - - - - - - - - - - - - - - - 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 32 80% 31 - 30 - 29 90% 28 100% 27 91 160 301 337 430 444 455 462 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 26 42 25 10% 24 20% 23 26 22 19 21 30% 20 40% 19 14 112 132 143 152 159 165 188 201 212 222 303 311 318 324 330 335 340 344 420 424 427 430 433 436 438 441 111 13
91 - - - - - - - - - - - - - - - - - - - 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 104 113 129 138 145 151 157 161 165 184 194 203 211 218 225 303 309 314 319 323 327 331 335 103 113 130 139 147 154 159 164 182 193 203 212 220 227 305 311 317 322 327 331 335 339 342 346 92 113 133 144 153 160 166 190 203 214 224 305 312
Liebert® APS™ 92 5 - - - - - - - - - - - - - - - - - - - - 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - 91 42 26 19 14 11 9 7 6 2 Load Level 1 100 44 27 20 15 11 9 8 6 5 160 99 62 46 37 28 25 20 18 16 3 145 73 46 34 26 20 17 14 12 10 301 144 104 76 53 47 41 35 28 26 4 167 105 67 47 38 28 25 21 18 16 337 166 138 108 83 69 52 48 43
27 45 30% 20% 10 11 12 13 14 15 17 18 19 20 # Battery Strings 16 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 104 113 129 138 145 151 157 161 165 184 194 203 211 218 225 303 309 314 319 323 327 331 335 338 341 344 347 9 103 113 130 139 147 154 159 164 182 193 203 212 220 227 305 311 317 322 327 331 335 339 342 346 421 423 426 429 92 8 113 133 144 153 160 166 190 203 214 224 305 312 319 325 331 336 341 345 421 425 428 431 434 437 439 442 444 446 448 101 113 132 142 150 157
Liebert® APS™ 94 13 14 15 16 17 18 19 20 # Battery Strings 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 102 113 130 139 147 154 159 164 181 193 203 211 219 227 305 311 317 322 327 331 335 339 342 345 420 423 426 429 19 26 42 91 160 301 337 430 444 455 462 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 30% 20% 10% 100% 90% 80
95 17 18 19 20 # Battery Strings 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 103 113 130 139 147 154 159 164 182 193 203 212 220 227 305 311 317 322 327 331 335 339 342 346 421 423 426 113 133 144 153 160 166 190 203 214 224 305 312 319 325 331 336 341 345 421 425 428 431 434 437 439 442 444 446 112 137 150 161 182 201 217 302 313 322 330 337 343 421 426 430 434 438 442 445 447 450 452 455 457 459 461 462 464 465 109 143 161 195 220 311 326 337 347 427 434 440 445 449 453 457 460 462
Liebert® APS™ 96 - - - - - - - - - - - - - - - - - - - - - - - - 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% - - - - - - - - - - - - - - - - - - - - - - - - 98 112 132 143 152 159 165 188 201 212 222 303 311 318 324 330 335 340 344 420 424 427 430 433 436 438 441 443 445 110 134 148 159 167 196 212 226 309 318 327 334 340 346 423 428 432 436 439 443 445 448 451 453 455 457 459 461 462
Specifications NOTES 97 Liebert® APS™
Specifications Liebert® APS™ 98