Instruction manual
17
g. Position gland clamping insert so the interior end is flush with the 
heat shrink.
h. Fold the cloth shield or braid and drain wires over the clamping 
insert and approximately 1/8 inch (3 mm) past the O-ring.
i. Install the gland body into the core processor housing conduit 
opening.
5. Insert the wires through the gland body and assemble the gland by 
tightening the gland nut.
6. Identify the wires in the 4-wire cable. The 4-wire cable supplied by 
Micro Motion consists of one pair of 18 AWG (0,75 mm
2
) wires (red 
and black), which should be used for the VDC connection, and one 
pair of 22 AWG (0,35 mm
2
) wire (green and white), which should be 
used for the RS-485 connection. Connect the four wires to the 
numbered slots on the core processor, matching corresponding 
numbered terminals on the transmitter. See Figure 12.
Shielded heat shrink completely covers exposed drain wires