Instruction manual
Micro Motion
®
 Model D and DT Sensors Instruction Manual 1
Before You Begin
Your new sensor
Your new Micro Motion
®
 Model D or DT sensor, or D600 sensor and 
booster amplifier, is one part of a Coriolis flowmetering system. The 
other part is a transmitter.
Transmitter connections
Model D sensors are available with a factory-supplied 9-wire junction 
box for connecting to a remotely mounted transmitter, or to a remotely 
mounted core processor.
Model DT sensors are available with a 3-foot (1-meter) pigtail of cable 
that connects to a user-supplied junction box. The junction box connects 
to a remotely mounted transmitter, or to a remotely mounted core 
processor.
The D600 has a booster amplifier. The booster amplifier is available with 
a factory-supplied 9-wire junction box for connecting to a remotely 
mounted transmitter, or with a factory-supplied core processor for 
connecting to a 4-wire remotely mounted transmitter or to a user-
supplied remote host.
All Model D and DT sensors may be connected to the Micro Motion 
transmitters listed in Table 1. The D600 sensor may be connected to the 
transmitters listed in Table 2.
Table 1. Transmitter and sensor compatibility guide
Transmitter
Model D sensor
(factory-supplied junction box)
Model DT sensor
(user-supplied junction box)
Model 1700/2700 (9-wire) X X
Model 3500/3700 (9-wire) X X
RFT9739 (7- or 9-wire) X X
IFT9701 (9-wire) X
(1)
RFT9712 (7- or 9-wire) X X
(1)Except D600.