Instruction manual
20 Micro Motion
®
 Model D and DT Sensors Instruction Manual
Wiring continued
Model D sensor junction box
Model DT sensor cable and 
junction box
Model DT sensors can use a junction box. Model DT sensors come with 
a 3-foot (1 meter) pigtail of pre-installed cable and a 3-foot (1 meter) 
piece of conduit that needs to be fitted over the pre-installed cable. See 
illustration on page 21.
• Slide the conduit over the pre-installed cable. 
• Screw the conduit fitting end into the sensor.
The other end of the conduit can be connected to a user-supplied 
junction box or directly to a transmitter.
• If the conduit is connected to a user-supplied junction box, connect the 
wires to the terminals on the junction box. If possible, install wiring with 
junction-box openings pointed downward, or with drip legs in the 
conduits or cables, to reduce the risk of condensation or excessive 
moisture in the junction box. Next, connect the 9-wire cable from the 
junction box to the transmitter by following the instructions in 
Connecting and shielding 9-wire cable.
• If the conduit is connected directly to a transmitter, refer to the wiring 
instructions in the transmitter Quick Reference Guide.
3/4" NPT female 
conduit opening
Drip leg in 
conduit or cable